Kudo K, Nagata T, Kimura K, Imamura T, Noda M
Department of Legal Medicine, Faculty of Medicine, Kyushu University, Fukuoka, Japan.
J Chromatogr. 1988 Oct 14;431(2):353-9. doi: 10.1016/s0378-4347(00)83103-5.
A reliable and sensitive capillary gas chromatographic-mass spectrometric method was developed for the detection and determination of diazepam and its major metabolite, N-desmethyldiazepam, in human material. Medazepam served as the internal standard. Quantitative determination was achieved using mass fragmentography with selected ions of m/z 256 for diazepam and m/z 242 for N-desmethyldiazepam and medazepam. The limit of detection was 1 ng/g and the recoveries were 98.54 +/- 3.95% for diazepam and 98.66 +/- 6.48% for N-desmethyldiazepam. The calibration graph was linear over the concentration range from 1.0 ng/g to 1.0 microgram/g for diazepam and N-desmethyldiazepam. Using this method, trace amounts of diazepam and N-desmethyldiazepam were detected in the tissues of an autopsied individual.