Suppr超能文献

STAT检测的挽歌:自动化与即时检验

Requiem for the STAT Test: Automation and Point of Care Testing.

作者信息

Singh Gurmukh, Savage Natasha M, Gunsolus Brandy, Foss Kellie A

机构信息

Professor of Pathology, Shepeard Chair in Clinical Pathology, Vice Chair of Pathology, Augusta, Georgia.

Associate Professor of Pathology, Director of Hematology and Hematopathology, Augusta, Georgia.

出版信息

Lab Med. 2020 Mar 10;51(2):e27-e31. doi: 10.1093/labmed/lmz080.

Abstract

OBJECTIVE

Quick turnaround of laboratory test results is needed for medical and administrative reasons. Historically, laboratory tests have been requested as routine or STAT. With a few exceptions, a total turnaround time of 90 minutes has been the usually acceptable turnaround time for STAT tests.

METHODS

We implemented front-end automation and autoverification and eliminated batch testing for routine tests. We instituted on-site intraoperative testing for selected analytes and employed point of care (POC) testing judiciously. The pneumatic tube system for specimen transport was expanded.

RESULTS

The in-laboratory turnaround time was reduced to 45 minutes for more than 90% of tests that could reasonably be ordered STAT. With rare exceptions, the laboratory no longer differentiates between routine and STAT testing. Having a single queue for all tests has improved the efficiency of the laboratory.

CONCLUSION

It has been recognized in manufacturing that batch processing and having multiple queues for products are inefficient. The same principles were applied to laboratory testing, which resulted in improvement in operational efficiency and elimination of STAT tests. We propose that the target for in-laboratory turnaround time for STAT tests, if not all tests, be 45 minutes or less for more than 90% of specimens.

摘要

目的

出于医疗和管理原因,需要快速获得实验室检测结果。从历史上看,实验室检测申请分为常规或急诊。除少数例外情况外,90分钟的总周转时间一直是急诊检测通常可接受的周转时间。

方法

我们实施了前端自动化和自动验证,并取消了常规检测的批量检测。我们为选定的分析物开展了现场术中检测,并谨慎采用即时检测(POC)。扩大了用于标本运送的气动管道系统。

结果

对于90%以上可合理申请急诊的检测项目,实验室内部周转时间缩短至45分钟。除极少数例外情况外,实验室不再区分常规检测和急诊检测。所有检测项目采用单一队列提高了实验室效率。

结论

制造业已经认识到,批量处理和为产品设置多个队列效率低下。这些相同的原则应用于实验室检测,从而提高了运营效率并取消了急诊检测。我们建议,如果不是所有检测项目,对于90%以上的标本,急诊检测的实验室内部周转时间目标应为45分钟或更短。