Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 327 E. 64th St., New York, NY 10065, USA.
Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 327 E. 64th St., New York, NY 10065, USA.
Clin Biochem. 2020 Mar;77:57-61. doi: 10.1016/j.clinbiochem.2019.12.010. Epub 2019 Dec 26.
We describe the use of MALDI-TOF mass spectrometry in the analysis of a suspected case of gamma heavy chain disease. The patient had an abnormal serum immunofixation result where a monoclonal gamma heavy chain band was present without a corresponding light chain. Analysis by MALDI-TOF mass spectrometry revealed large peaks in the spectrum following IgG-specific purification. The m/z values of the peaks were outside the expected range for normal heavy chains or light chains. Corresponding peaks were not present in mass spectra of the kappa- or lambda-specific purifications. MALDI-TOF MS confirmed the presence of a truncated heavy chain without associated light chains. This case report demonstrates the value of mass spectrometry in interpreting challenging cases such as the identification of heavy chain disease.
我们描述了 MALDI-TOF 质谱分析在疑似γ重链病中的应用。该患者的血清免疫固定电泳结果异常,出现单克隆γ重链带,而没有相应的轻链。MALDI-TOF 质谱分析显示,在 IgG 特异性纯化后,图谱中出现了大的峰。峰的 m/z 值超出了正常重链或轻链的预期范围。κ或λ特异性纯化的质谱中没有相应的峰。MALDI-TOF MS 证实存在截断的重链,而没有相关的轻链。本病例报告证明了质谱在解释此类具有挑战性的病例(如重链病的鉴定)中的价值。