Pre-contrast T1 and cartilage thickness as confounding factors in dGEMRIC when evaluating human cartilage adaptation to physical activity.

机构信息

Orthopaedics, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden.

Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö, Sweden.

出版信息

BMC Med Imaging. 2019 Dec 31;20(1):1. doi: 10.1186/s12880-019-0399-0.

Abstract

BACKGROUND

The dGEMRIC (delayed Gadolinium-Enhanced MRI of Cartilage) technique has been used in numerous studies for quantitative in vivo evaluation of the relative glycosaminoglycan (GAG) content in cartilage. The purpose of this study was to determine the influence of pre-contrast T1 and cartilage thickness when assessing knee joint cartilage quality with dGEMRIC.

METHODS

Cartilage thickness and T1 relaxation time were measured in the central part of the femoral condyles before and two hours after intravenous Gd-DTPA administration in 17 healthy volunteers from a previous study divided into two groups: 9 sedentary volunteers and 8 exercising elite runners. Results were analyzed in superficial and a deep weight-bearing, as well as in non-weight-bearing regions of interest.

RESULTS

In the medial compartment, the cartilage was thicker in the exercising group, in weight-bearing and non-weight-bearing segments. In most of the segments, the T1 pre-contrast value was longer in the exercising group compared to the sedentary group. Both groups had a longer pre-contrast T1 in the superficial cartilage than in the deep cartilage. In the superficial cartilage, the gadolinium concentration was independent of cartilage thickness. In contrast, there was a linear correlation between the gadolinium concentration and cartilage thickness in the deep cartilage region.

CONCLUSION

Cartilage pre-contrast T1 and thickness are sources of error in dGEMRIC that should be considered when analysing bulk values. Our results indicate that differences in cartilage structure due to exercise and weight-bearing may be less pronounced than previously demonstrated.

摘要

背景

dGEMRIC(延迟钆增强 MRI 软骨成像)技术已在许多研究中用于定量评估软骨中相对糖胺聚糖(GAG)含量的体内变化。本研究旨在探讨在评估膝关节软骨质量时,预对比 T1 值和软骨厚度对 dGEMRIC 的影响。

方法

在先前研究中,17 名健康志愿者被分为两组:9 名久坐志愿者和 8 名精英跑步运动员,分别在静脉注射 Gd-DTPA 前和两小时后测量股骨髁中央部分的软骨厚度和 T1 弛豫时间。结果在浅表和深层负重以及非负重感兴趣区进行分析。

结果

在膝关节内侧间室,运动组的软骨在负重和非负重区域均较厚。与久坐组相比,运动组在大多数区域的预对比 T1 值较长。两组的浅层软骨的预对比 T1 值均长于深层软骨。在浅层软骨中,钆浓度与软骨厚度无关。相比之下,在深层软骨区域,钆浓度与软骨厚度呈线性相关。

结论

dGEMRIC 中的软骨预对比 T1 值和厚度是误差源,在分析整体值时应予以考虑。我们的结果表明,由于运动和负重导致的软骨结构差异可能不如之前所显示的那么明显。