Usman Rashid, Ahmed Hafsa, Ahmed Zeeshan, Ali Maqsood
Department of Surgery, Mid City Hospital, Lahore, Pakistan.
Department of Anesthesia, Mid City Hospital, Lahore, Pakistan.
J Coll Physicians Surg Pak. 2020 Jan;30(1):85-87. doi: 10.29271/jcpsp.2020.01.85.
Trocar injury to abdominal aorta is uncommon and even rare with optical trocars. Such injury, resulting from umbilical trocar insertion, is potentially fatal. It often causes on-table death due to torrential life-threatening haemorrhage and unavailability of expert vascular help. We present a rare case of an injury to infra-renal abdominal aorta, caused by optical trocar insertion for bariatric surgery. Immediate recognition of the injury, deployment of life-saving manoeuvres, timely resuscitation, followed by definitive repair of aorta by vascular surgeon was life-saving for this patient. The recovery phase was uneventful and patient had no residual clinical problems during follow-up.
套管针损伤腹主动脉并不常见,使用光学套管针时更是罕见。这种由脐部套管针插入导致的损伤可能是致命的。它常因危及生命的大出血且无法获得专业血管外科帮助而导致术中死亡。我们报告一例罕见的因肥胖症手术中插入光学套管针导致肾下腹主动脉损伤的病例。对损伤的及时识别、采取挽救生命的措施、及时复苏,随后由血管外科医生对主动脉进行确定性修复,挽救了该患者的生命。恢复阶段顺利,患者在随访期间没有残留的临床问题。