Suppr超能文献

经控制应用 GentaColl 海绵后,通过微透析在猪模型中获得的庆大霉素局部浓度。

Local concentrations of gentamicin obtained by microdialysis after a controlled application of a GentaColl sponge in a porcine model.

机构信息

Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.

Institute of Clinical Medicine, Aarhus University Hospital, Aarhus, Denmark.

出版信息

J Orthop Res. 2020 Aug;38(8):1793-1799. doi: 10.1002/jor.24588. Epub 2020 Jan 20.

Abstract

Local treatment with gentamicin may be an important tool in the prevention and treatment of surgical site infections in high-risk procedures and patients. The aim of this study was to evaluate the pharmacokinetic profile of gentamicin in bone and surrounding tissue, released from a controlled application of a GentaColl sponge in a porcine model. In eight female pigs, a GentaColl sponge of 10 × 10 cm (1.3 mg gentamicin/cm ) was placed in a cancellous bone cavity in the proximal tibia. Microdialysis was used for sampling of gentamicin concentrations over 48 hours from the cavity with the implanted GentaColl sponge, cancellous bone parallel to the cavity over and under the epiphyseal plate, cortical bone, the intramedullary canal, subcutaneous tissue, and the joint cavity of the knee. Venous blood samples were obtained as reference. The main finding was a mean peak drug concentration (95% CI) of gentamicin in the cancellous bone cavity containing the implanted GentaColl sponge of 11 315 (9049-13 581) μg/mL, persisting above 1000 μg/mL until approximately 40 hours after application. Moreover, the concentrations were low (<1 μg/mL) in the surrounding tissues as well as in plasma. The mean peak gentamicin concentration from the cancellous bone cavity after a controlled application of a GentaColl sponge was high and may be adequate for the prevention of biofilm formation. However, high MIC strains and uncontrolled application of the GentaColl sponge may jeopardize this conclusion.

摘要

局部应用庆大霉素可能是预防和治疗高危手术和患者手术部位感染的重要手段。本研究旨在评估 Gentacoll 海绵在猪模型中控制应用时骨和周围组织中释放的庆大霉素的药代动力学特征。在 8 头雌性猪中,将 10×10 cm(1.3mg 庆大霉素/cm )的 Gentacoll 海绵置于胫骨近端的松质骨腔中。在植入 Gentacoll 海绵的骨腔中,使用微透析法在 48 小时内取样庆大霉素浓度,同时在骺板上下、骨皮质、骨髓腔、皮下组织和膝关节关节腔中取样松质骨平行的腔中的庆大霉素浓度。采集静脉血样作为参考。主要发现是植入 Gentacoll 海绵的松质骨腔中庆大霉素的平均峰值药物浓度(95%CI)为 11,315(9,049-13,581)μg/mL,持续高于 1000μg/mL 直至应用后约 40 小时。此外,周围组织和血浆中的浓度较低(<1μg/mL)。Gentacoll 海绵控制应用后,松质骨腔中的平均庆大霉素峰值浓度较高,可能足以预防生物膜形成。然而,高 MIC 菌株和 Gentacoll 海绵的不受控制应用可能会危及这一结论。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验