Abstract

PURPOSE

To compare one-year visual outcomes and optical quality after femtosecond laser small incision lenticule extraction (SMILE) and Visian Implantable Collamer Lens with a central hole (ICL V4c) implantation for high myopia.

METHODS

This prospective non-randomized study included 37 eyes of 20 patients who underwent SMILE (G-S) and 39 eyes of 20 patients who underwent ICL V4c implantation (G-V). Spherical equivalent (SE), uncorrected distance visual acuity, corrected distance visual acuity, retinal image quality and intraocular scattering were evaluated at one year after surgery. Each model was adjusted for age, gender, eye and preoperative SE during treatment.

RESULTS

At the one-year follow-up, G-S and G-V showed similar safety index (1.13 ± 0.13 and 1.11 ± 0.15, respectively) and efficacy index (1.05 ± 0.14 and 1.06 ± 0.15, respectively). All 21 eyes with Toric ICL (TICL) had a postoperative astigmatism of ≤0.5 dioptres (D), while the astigmatism was ≤0.5 D in all G-S eyes. Thirty-six G-S eyes (97%) and 35 G-V eyes (90%) were within ± 0.5 D of the target SE. The changes in the modulation transfer function cut-off frequency (MTF ) and the objective scatter index from before operation to one year following the operation were not significantly different between the groups (p = 0.523 and 0.826, respectively).

CONCLUSION

Both SMILE and ICL V4c implantation provide good safety, efficacy, predictability, and stability in correcting high myopia. Optical quality including intraocular scattering was great and relatively stable in both groups during the one-year observation period.

摘要

目的

比较飞秒激光小切口角膜微透镜取出术(SMILE)联合中央孔型可植入式隐形眼镜(ICL V4c)与 ICL V4c 植入术矫正高度近视的一年视觉效果和光学生物测量结果。

方法

前瞻性非随机研究纳入 20 名患者(37 眼)行 SMILE(G-S)和 20 名患者(39 眼)行 ICL V4c 植入术(G-V)。术后一年,评估等效球镜(SE)、未矫正远视力、矫正远视力、视网膜成像质量和眼内散射。在治疗过程中,每个模型均根据年龄、性别、眼别和术前 SE 进行调整。

结果

在一年的随访中,G-S 和 G-V 的安全性指数(分别为 1.13±0.13 和 1.11±0.15)和有效性指数(分别为 1.05±0.14 和 1.06±0.15)相似。所有 21 例 TICL 术后散光均≤0.5 屈光度(D),而 G-S 术后所有散光均≤0.5 D。36 只 G-S 眼(97%)和 35 只 G-V 眼(90%)术后 SE 均在±0.5 D 以内。术后一年两组间调制传递函数截止频率(MTF)和客观散射指数(OSI)的变化无统计学差异(p=0.523 和 0.826)。

结论

SMILE 和 ICL V4c 植入术矫正高度近视均具有良好的安全性、有效性、可预测性和稳定性。在一年的观察期内,两组的光学质量(包括眼内散射)均良好且相对稳定。