Suppr超能文献

Microwave reflectometer for density profile and turbulence measurements on the COMPASS tokamak.

作者信息

Bogar O, Zajac J, Zacek F, Varavin M, Hron M, Panek R, Silva A

机构信息

Institute of Plasma Physics, The Czech Academy of Sciences, 182 00 Prague, Czech Republic.

Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico da Universidade de Lisboa, 1049-001 Lisboa, Portugal.

出版信息

Rev Sci Instrum. 2020 Jan 1;91(1):013515. doi: 10.1063/1.5099345.

Abstract

The fast microwave reflectometer system on the COMPASS tokamak consists of an O-mode polarized K-band (18 GHz-26 GHz), Ka-band (26 GHz-40 GHz), and a part of U-band (40 GHz-54 GHz). The plasma density profile from the edge plasma area is measured using a fast sweeping rate up of to 6 µs of the probing wave. The processing of the reflected signal is realized by the heterodyne detection configuration based on the I/Q modulator. Two different methods of dynamic calibration of the required linear sweep frequency, together with static frequency and dispersion calibration, were used. The electron density profile was reconstructed by a spectrogram-based method with four sweeps on average. The system has the capability to measure the mid-plane low-field side electron density profile in the density range from 4 × 10 m to 3.6 × 10 m. Experimental results obtained on COMPASS discharges are presented to demonstrate the performance of the diagnostics.

摘要

相似文献

1
Microwave reflectometer for density profile and turbulence measurements on the COMPASS tokamak.
Rev Sci Instrum. 2020 Jan 1;91(1):013515. doi: 10.1063/1.5099345.
5
Microwave Doppler reflectometer system in the Experimental Advanced Superconducting Tokamak.
Rev Sci Instrum. 2013 Oct;84(10):103511. doi: 10.1063/1.4825344.
6
A frequency-modulated continuous-wave reflectometer for the Lithium Tokamak Experiment.
Rev Sci Instrum. 2017 May;88(5):053502. doi: 10.1063/1.4981811.
7
frequency calibration of frequency modulated continuous wave reflectometry.
Rev Sci Instrum. 2018 Oct;89(10):10H121. doi: 10.1063/1.5038829.
8
Development of a tunable multi-channel Doppler reflectometer on J-TEXT tokamak.
Rev Sci Instrum. 2021 Mar 1;92(3):033545. doi: 10.1063/5.0040915.
9
Edge scanning reflectometry for density profile measurement on the SPARC tokamak.
Rev Sci Instrum. 2024 Aug 1;95(8). doi: 10.1063/5.0219533.
10
A novel multi-channel quadrature Doppler backward scattering reflectometer on the HL-2A tokamak.
Rev Sci Instrum. 2016 Nov;87(11):113501. doi: 10.1063/1.4966680.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验