Jelsma Jetse, Schotanus Martijn, Kleinveld Henne, Grimm Bernd, Heyligers Ide
Department of Orthopedic Surgery, Zuyderland Medical Centre, Sittard-Geleen, the Netherlands.
Department of Clinical Chemistry, Zuyderland Medical Centre, Sittard-Geleen, the Netherlands.
J Orthop. 2020 Jan 25;18:213-217. doi: 10.1016/j.jor.2020.01.032. eCollection 2020 Mar-Apr.
An increase in blood serum metal ion levels is seen after implantation of all metal-on-metal (MoM) hip prosthesis. Systemic complaints contributed to raised cobalt ion concentrations in patients with MoM arthroplasty may lead to a variety of symptoms. The aim of this study is to investigate self-reported systemic complaints in association with cobalt ion concentrations in patients with any type of MoM hip prosthesis.
A cohort study was conducted. Patients with both unilateral and bilateral, resurfacing and large head metal on metal total hip arthroplasties (LHMoM THA) were included. Cobalt ion concentrations were measured by inductively coupled plasma mass spectrometry. Based on the known cobalt toxicity symptoms of case-reports and toxicology reports a new non-validated questionnaire was developed. Analysis was performed on two groups; a low cobalt ion concentration group and a high cobalt ion concentration group.
A total of 62 patients were included with a mean age at surgery of 60.8 ± 9.3 years and a mean follow up of 6.3 ± 1.4 years. Mean cobalt ion concentrations were 104 ± 141 nmol/L (9-833). Based on the different thresholds (120-170 or 220 nmol/L) the low cobalt ion concentration group consisted of 44 (71%), 51 (82%) or 55 (89%) subjects respectively. In the 120 nmol/L and 170 nmol/L thresholds a significant difference in age was found. The composite score for OVS increased from 54% to 57%-68% with rising threshold value, a hint at the correlation between ion concentration and symptom prevalence.
Ocular-vestibular symptoms were more common in high cobalt ion concentration groups for the three threshold levels tested and with increasing prevalence for higher threshold values. With regards to proactively inquired, self-reported symptoms the threshold where effects may be present could be lower than values currently applied in clinical follow-up.
所有金属对金属(MoM)髋关节假体植入后,血清金属离子水平都会升高。MoM关节成形术患者中,全身性不适导致钴离子浓度升高,可能会引发多种症状。本研究旨在调查任何类型MoM髋关节假体患者自我报告的全身性不适与钴离子浓度之间的关系。
进行了一项队列研究。纳入单侧和双侧、表面置换和大头金属对金属全髋关节置换术(LHMoM THA)的患者。通过电感耦合等离子体质谱法测量钴离子浓度。基于病例报告和毒理学报告中已知的钴中毒症状,开发了一份新的未经验证的问卷。对两组进行分析,即低钴离子浓度组和高钴离子浓度组。
共纳入62例患者,手术时的平均年龄为60.8±9.3岁,平均随访时间为6.3±1.4年。平均钴离子浓度为104±141 nmol/L(9 - 833)。根据不同阈值(120 - 170或220 nmol/L),低钴离子浓度组分别由44例(71%)、51例(82%)或55例(89%)受试者组成。在120 nmol/L和170 nmol/L阈值时,发现年龄存在显著差异。随着阈值升高,OVS综合评分从54%增加到57% - 68%,这暗示了离子浓度与症状患病率之间的相关性。
在所测试的三个阈值水平下,高钴离子浓度组的眼前庭症状更为常见,且随着阈值升高患病率增加。对于主动询问的自我报告症状,可能出现影响的阈值可能低于目前临床随访中应用的值。