Suppr超能文献

特定血糖范围内的时间、血糖管理指标和血糖变异性:连续血糖监测 (CGM) 系统模型和传感器对 CGM 指标的影响。

Time in Specific Glucose Ranges, Glucose Management Indicator, and Glycemic Variability: Impact of Continuous Glucose Monitoring (CGM) System Model and Sensor on CGM Metrics.

机构信息

Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Germany.

出版信息

J Diabetes Sci Technol. 2021 Sep;15(5):1104-1110. doi: 10.1177/1932296820931825. Epub 2020 Jun 8.

Abstract

BACKGROUND

International consensus recommends a set of continuous glucose monitoring (CGM) metrics to assess quality of diabetes therapy. The impact of individual CGM sensors on these metrics has not been thoroughly studied yet. This post hoc analysis aimed at comparing time in specific glucose ranges, coefficient of variation (CV) of glucose concentrations, and glucose management indicator (GMI) between different CGM systems and different sensors of the same system.

METHOD

A total of 20 subjects each wore two Dexcom G5 (G5) sensors and two FreeStyle Libre (FL) sensors for 14 days in parallel. Times in ranges, GMI, and CV were calculated for each 14-day sensor experiment, with up to four sensor experiments per subject. Pairwise differences between different sensors of the same CGM system as well as between sensors of different CGM system were calculated for these metrics.

RESULTS

Pairwise differences between sensors of the same model showed larger differences and larger variability for FL than for G5, with some subjects showing considerable differences between the two sensors. When pairwise differences between sensors of different CGM models were calculated, substantial differences were found in some subjects (75th percentiles of differences of time spent <70 mg/dL: 5.0%, time spent >180 mg/dL: 9.2%, and GMI: 0.42%).

CONCLUSION

Relevant differences in CGM metrics between different models of CGM systems, and between different sensors of the same model, worn by the same study subjects were found. Such differences should be taken into consideration when these metrics are used in the treatment of diabetes.

摘要

背景

国际共识推荐了一套连续血糖监测(CGM)指标,用于评估糖尿病治疗的质量。但单个 CGM 传感器对这些指标的影响尚未得到充分研究。本研究旨在比较不同 CGM 系统和同一系统的不同传感器之间的特定血糖范围内的时间、血糖浓度变异系数(CV)和血糖管理指标(GMI)。

方法

共有 20 名受试者,每位受试者同时佩戴两个 Dexcom G5(G5)传感器和两个 FreeStyle Libre(FL)传感器,持续 14 天。每个 14 天的传感器实验计算了时间范围、GMI 和 CV,每个受试者最多有四个传感器实验。对同一 CGM 系统的不同传感器以及不同 CGM 系统的传感器之间的这些指标进行了成对差异比较。

结果

同一型号传感器之间的成对差异显示,FL 的差异较大且变异较大,而 G5 的差异较小且变异较小,一些受试者两个传感器之间的差异较大。当计算不同 CGM 模型传感器之间的成对差异时,一些受试者发现差异较大(<70mg/dL 的时间百分比差异的第 75 个百分位数:5.0%,>180mg/dL 的时间百分比差异:9.2%,GMI 差异:0.42%)。

结论

同一研究对象佩戴的不同 CGM 系统模型之间以及同一模型的不同传感器之间的 CGM 指标存在相关差异。在糖尿病治疗中使用这些指标时,应考虑这些差异。

相似文献

2
Choice of Continuous Glucose Monitoring Systems May Affect Metrics: Clinically Relevant Differences in Times in Ranges.
Exp Clin Endocrinol Diabetes. 2022 May;130(5):343-350. doi: 10.1055/a-1347-2550. Epub 2021 Jan 28.
4
Within-Person and Between-Sensor Variability in Continuous Glucose Monitoring Metrics.
Clin Chem. 2023 Feb 1;69(2):180-188. doi: 10.1093/clinchem/hvac192.
5
Feasibility of intraoperative continuous glucose monitoring: An observational study in general surgery patients.
J Clin Anesth. 2023 Aug;87:111090. doi: 10.1016/j.jclinane.2023.111090. Epub 2023 Mar 11.
6
Limitations of 14-Day Continuous Glucose Monitoring Sampling for Assessment of Hypoglycemia and Glycemic Variability in Type 1 Diabetes.
Diabetes Technol Ther. 2024 Jul;26(7):503-508. doi: 10.1089/dia.2023.0476. Epub 2024 Feb 16.
7
The Relationship Between CGM-Derived Metrics, A1C, and Risk of Hypoglycemia in Older Adults With Type 1 Diabetes.
Diabetes Care. 2020 Oct;43(10):2349-2354. doi: 10.2337/dc20-0016. Epub 2020 May 27.

引用本文的文献

2
Time in range-A new gold standard in type 2 diabetes research?
Diabetes Obes Metab. 2025 May;27(5):2342-2362. doi: 10.1111/dom.16279. Epub 2025 Feb 25.
7
Discordance Between Glycated Hemoglobin A1c and the Glucose Management Indicator in People With Diabetes and Chronic Kidney Disease.
J Diabetes Sci Technol. 2023 Nov;17(6):1553-1562. doi: 10.1177/19322968221092050. Epub 2022 Apr 25.
8
Variation of Mean Absolute Relative Differences of Continuous Glucose Monitoring Systems Throughout the Day.
J Diabetes Sci Technol. 2022 May;16(3):649-658. doi: 10.1177/1932296821992373. Epub 2021 Feb 20.

本文引用的文献

2
Associations between HbA and continuous glucose monitoring-derived glycaemic variables.
Diabet Med. 2019 Dec;36(12):1637-1642. doi: 10.1111/dme.14065. Epub 2019 Jul 17.
5
Performance and Usability of Three Systems for Continuous Glucose Monitoring in Direct Comparison.
J Diabetes Sci Technol. 2019 Sep;13(5):890-898. doi: 10.1177/1932296819826965. Epub 2019 Feb 7.
6
Glucose Management Indicator (GMI): A New Term for Estimating A1C From Continuous Glucose Monitoring.
Diabetes Care. 2018 Nov;41(11):2275-2280. doi: 10.2337/dc18-1581. Epub 2018 Sep 17.
8
Prediction Quality of Glucose Trend Indicators in Two Continuous Tissue Glucose Monitoring Systems.
Diabetes Technol Ther. 2018 Aug;20(8):550-556. doi: 10.1089/dia.2018.0112.
10
International Consensus on Use of Continuous Glucose Monitoring.
Diabetes Care. 2017 Dec;40(12):1631-1640. doi: 10.2337/dc17-1600.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验