Abstract

The method using ethanol to evaluate the cellulose insulation aging condition of oil-immersed transformers has been proposed. At present, the dominating method for detecting ethanol in insulating oil is to use headspace-gas-chromatography-mass-spectrometry (HS-GC-MS). However, the problem of quantitative inaccuracy will be sometimes encountered in the actual detection process due to improper instrument parameter setting and improper manual operation. In this study, as an aging marker, ethanol in transformer insulating oil was separated by using VF-624 ms capillary column. The effects of gas-chromatography-mass-spectrometry (GC-MS) optimization conditions, headspace equilibrium temperature, headspace equilibrium time and standard solution preparation method on the determination of ethanol content in oil were discussed, and optimized measures were proposed. The experimental results showed that the measurement can be more accurate under the headspace temperature of 80 °C and the headspace time of 40 min, and relative standard deviation percentage (RSD%) could reach to 4.62% under this condition. It was also pointed out that, for the preparation of standard solution, the method which controlled the sampling volume of anhydrous ethanol by microliter syringe could make the peak area of ethanol chromatogram have a better linear relationship with the standard curve. Under the similar linear range, the goodness of fitting curve without diluting process could be as high as 0.9993, while the method of preparing the stock solution and diluting stepwise to obtain the fitting curve only had a goodness of 0.9910. The method was validated by standard addition recovery test, and the recovery values obtained were between 90.3% and 95.8%. The optimized method is of great significance for the measurement of ethanol dissolved in insulating oil.

摘要

提出了利用乙醇评估油浸式变压器纤维素绝缘老化状况的方法。目前,绝缘油中乙醇检测的主导方法是顶空气相色谱 - 质谱联用(HS - GC - MS)。然而,在实际检测过程中,由于仪器参数设置不当和人工操作不当,有时会遇到定量不准确的问题。本研究中,以变压器绝缘油中的乙醇作为老化标志物,采用VF - 624 ms毛细管柱进行分离。探讨了气相色谱 - 质谱联用(GC - MS)优化条件、顶空平衡温度、顶空平衡时间和标准溶液配制方法对油中乙醇含量测定的影响,并提出了优化措施。实验结果表明,在顶空温度80℃、顶空时间40 min的条件下测量更准确,在此条件下相对标准偏差百分比(RSD%)可达4.62%。还指出,对于标准溶液的配制,用微量注射器控制无水乙醇进样量的方法可使乙醇色谱峰面积与标准曲线具有更好的线性关系。在相似的线性范围内,不经稀释过程得到的拟合曲线拟合优度可达0.9993,而先配制储备液再逐步稀释得到拟合曲线的方法拟合优度仅为0.9910。通过标准加入回收试验对该方法进行了验证,得到的回收率在90.3%至95.8%之间。该优化方法对绝缘油中溶解乙醇的测量具有重要意义。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验