Effect of supporting implants inclination on stability of fixed partial denture: A finite element study.

机构信息

Faculty of Science & Technology, University of Mascara, Mascara, Algeria.

Laboratory of Mechanics and Materials Physics (LMPM), Mechanical Engineering Department, University of Sidi Bel-Abbes, Sidi Bel Abbès, Algeria.

出版信息

Proc Inst Mech Eng H. 2020 Oct;234(10):1162-1171. doi: 10.1177/0954411920944109. Epub 2020 Jul 20.

Abstract

The aim of this finite element study was to analyze effect of supporting implants inclination on stress distribution in the bone for a four-unit fixed partial denture. A three-dimensional finite element model of mandibular molar section of the bone to receive implants was constructed. Three implant-supported fixed partial dentures, with null, moderate and wide tilting, of 0°, 15° and 30° implant inclinations, respectively, were modeled. A mechanical load of 10 MPa was applied in coronal-apical direction on bridge framework at the regions of crowns positions. The finite element analysis was performed, and von Mises stress levels were calculated. Peak stress concentration in the cortical bone was observed mostly around the implant necks, in inter-implants line. There was favorable stress distribution during loading, with peak stress being 90.04 MPa for 0°, which decreased to 54.33 MPa for 15° and 46.36 MPa for 30° inclination. The supporting implants inclination in fixed partial denture plays an important role in stress distribution and may be helpful in preventing bone loss and implant failure. This phenomenon is likely to be more pronounced in bones of poor quality. Within the limitation of this study, it seems that the inclination of implants in fixed partial denture has a favorable effect on stress distribution pattern values around the supporting implants.

摘要

本有限元研究旨在分析四单位固定局部义齿中支撑种植体倾斜对骨内应力分布的影响。构建了下颌磨牙区段骨接收种植体的三维有限元模型。模拟了三种种植体支持的固定局部义齿,倾斜角度分别为 0°、15°和 30°,无倾斜、中度倾斜和宽倾斜。在桥体框架的牙冠位置区域,沿冠根向施加 10 MPa 的机械载荷。进行有限元分析并计算 von Mises 等效应力水平。皮质骨中的最大应力集中主要发生在种植体颈部周围,以及种植体之间的区域。在加载过程中,应力分布良好,0°时的最大峰值应力为 90.04 MPa,15°时降低至 54.33 MPa,30°时降低至 46.36 MPa。固定局部义齿中支撑种植体的倾斜对应力分布有重要影响,可能有助于防止骨丢失和种植体失败。在骨质量较差的情况下,这种现象可能更为明显。在本研究的限制范围内,似乎固定局部义齿中种植体的倾斜对支撑种植体周围的应力分布模式值有有利影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验