Verdant A, Pagé A, Baillot R, Lavoie C
Department of Cardiovascular and Thoracic Surgery, Hôpital du Sacré-Coeur, Université de Montréal, PQ.
Can J Surg. 1988 Jan;31(1):52-4.
A new method of temporary external shunting for total replacement of the aortic arch is described. Its greatest advantage is that systemic heparinization is not required. In a 46-year-old man total body perfusion was achieved with two 9-mm Gott aneurysm shunts inserted between the ascending aorta and both femoral arteries. Blood supply to the brain was maintained with the cut halves of a 7-mm Gott shunt connected as side branches to one of the 9-mm shunts, allowing cannulation of both carotid arteries. The total cardiac output, measured at 4.7 L/min by the thermodilution technique through a Swan-Ganz catheter, was propelled through these preheparinized multibranch shunts. A flowmeter adapted on one of the 9-mm Gott shunts demonstrated a shunt flow of 2000 ml/min and it was deduced that the other 2700 ml of the total cardiac output was delivered by the other shunt. During the 29 minutes of cross-clamping, there was no change in the filling pressure of either the right heart (central venous pressure 5 cm H2O) or the left heart (pulmonary wedge pressure 8 mm Hg). Aortic continuity was reestablished with the interposition of a 34-mm tubular woven Dacron prosthesis, on which two 10-mm woven Dacron side branches were anastomosed to the innominate and left common carotid arteries. The patient had no neurologic deficit and had normal physiologic function of all other organs.
描述了一种用于全主动脉弓置换的临时体外分流新方法。其最大优点是无需全身肝素化。在一名46岁男性患者中,通过在升主动脉和双侧股动脉之间插入两根9毫米的戈特动脉瘤分流管实现了全身灌注。用一根7毫米戈特分流管的两半作为侧支连接到一根9毫米分流管上,以维持脑部血液供应,从而可以对双侧颈动脉进行插管。通过一根 Swan-Ganz 导管采用热稀释技术测得的心输出量为4.7升/分钟,通过这些预先肝素化的多分支分流管进行推动。安装在一根9毫米戈特分流管上的流量计显示分流流量为2000毫升/分钟,由此推断总心输出量的另外2700毫升由另一根分流管输送。在29分钟的交叉钳夹期间,右心(中心静脉压5厘米水柱)或左心(肺楔压8毫米汞柱)的充盈压力均无变化。通过植入一根34毫米的编织涤纶人工血管重建主动脉连续性,在该人工血管上,两根10毫米的编织涤纶侧支与无名动脉和左颈总动脉进行了吻合。患者无神经功能缺损,所有其他器官的生理功能正常。