SUNY Upstate Medical University, Syracuse, NY, USA.
Eur J Orthop Surg Traumatol. 2021 Apr;31(3):435-440. doi: 10.1007/s00590-020-02775-3. Epub 2020 Sep 10.
A retrograde fibular medullary screw may be utilized in certain fractures about the ankle. The purpose of this study is to investigate the anatomic considerations of a retrograde medullary screw inserted from a lateral starting point to nearby anatomic structures about the distal fibula.
Ten fresh-frozen cadaveric lower extremities were utilized. A 1.6-mm Kirschner wire was inserted into the distal fibula from a far-lateral starting point. A 3.2-mm cannulated drill bit was then inserted over the Kirschner wire. After placement of the drill bit, dissection of the lateral ankle was undertaken. The proximity of nearby anatomic structures to the drill bit was measured using calipers. A 4.5-mm cortical screw was then inserted using fluoroscopic guidance. Measurements were then taken again to assess the relationship of the screw head to adjacent structures.
Mean distance from drill bit to nearby structures is as follows: Peroneus longus tendon 4.56 mm, peroneus brevis tendon 6.62 mm, sural nerve 4.13 mm, superior peroneal retinaculum 7.52 mm, inferior peroneal retinaculum 6.61 mm, anterior talofibular ligament (ATFL) 6.1 mm, calcaneofibular ligament (CFL) 6.7 mm. Average distance from 4.5-mm screw head to nearby structures is as follows: peroneus longus tendon 6.79 mm, peroneus brevis tendon 6.73 mm, ATFL 4.16 mm, CFL 5.14 mm, lateral talar process 9.41 mm.
Retrograde medullary fibular screw fixation may be safely carried out through a lateral start point. Anatomic structures about the lateral ankle are nearby but not immediately adjacent to the drill bit.
逆行腓骨髓内钉可用于踝关节周围的某些骨折。本研究旨在探讨从外侧起点逆行插入腓骨髓内钉至腓骨远端附近解剖结构的解剖学考虑。
使用 10 个新鲜冷冻的下肢尸体标本。从远外侧起点将 1.6mm 的克氏针插入腓骨远端。然后将 3.2mm 的空心钻套在克氏针上。插入钻头后,进行外踝切开术。使用卡尺测量附近解剖结构与钻头的接近程度。然后在透视引导下插入 4.5mm 的皮质螺钉。再次进行测量以评估螺钉头与相邻结构的关系。
钻头与附近结构的平均距离如下:腓骨长肌肌腱 4.56mm,腓骨短肌肌腱 6.62mm,腓肠神经 4.13mm,外踝上支持带 7.52mm,外踝下支持带 6.61mm,前距腓韧带(ATFL)6.1mm,跟腓韧带(CFL)6.7mm。4.5mm 螺钉头与附近结构的平均距离如下:腓骨长肌肌腱 6.79mm,腓骨短肌肌腱 6.73mm,ATFL 4.16mm,CFL 5.14mm,外踝尖 9.41mm。
逆行腓骨髓内钉固定可安全地从外侧起点进行。外踝周围的解剖结构虽然接近但并不紧邻钻头。