Eustachian tube function test as a predictor of middle ear barotrauma.

机构信息

MBAT Varna MMA Bulgaria, 'Christo Smirnenski' 3 str, 9000 Varna, Bulgaria.

Department of aviation and maritime medicine Military Medical Academy Sofiq, Georgi Sofijski 3 str, 1000 Sofia, Bulgaria.

出版信息

Int Marit Health. 2020;71(3):195-200. doi: 10.5603/IMH.2020.0035.

Abstract

BACKGROUND

Most of the cases of middle ear barotrauma in divers are due to the impassability of the Eustachian tube. The aim of our study is to compare the results of tympanometry and Valsalva part of Eustachian Tube Function test (ЕТF-test) with the ability of divers to compensate for the change in ambient pressure in a hyperbaric chamber.

MATERIAL AND METHODS

The study included 35 professional divers undergoing annual medical examination. For all subjects is measured first intratympanal pressure at rest, then after the maneuver of Valsalva with impedancemeter. Then a barofunction test (BFT) was performed to assess the diving fitness and the passability of the Eustachian tubes. It consists of divers compressing and decompressing in a hyperbaric chamber to a pressure of 2.2 ATA for 1 minute. Based on results from previous studies we are using a 20 DaPa cutoff point on the ETF test to predict Eustachian tube passability and a successful barofunction test.

RESULTS

In the current study 24 divers have ETF test results higher than 20 DaPa. 3 divers have ETF test values lower than 20 DaPa in both ears, but none of them displayed difficulties in the BFT. 8 divers have ETF values lower than 20 DaPa in one ear and higher than 20 DaPa in the other. 7 of the last group displayed difficulties with the BFT in the ear with poor ETF result.

CONCLUSIONS

We consider that the ETF test can be used to assess diving fitness as a screening method before performing a BFT, as values above 20 DaPa guarantee Eustachian tube function sufficient for diving activities. Values of 20 DaPa and less are not a definite predictor of the BFT results. The results of the ETF test can also be used in the usual work of an otorhinolaryngologist to evaluate Eustachian function in cases of unilateral disease of middle ear.

摘要

背景

潜水员中耳气压伤的大多数病例是由于咽鼓管不通。我们研究的目的是比较鼓室压测量和咽鼓管功能测试(ЕТF-测试)的瓦尔萨尔瓦部分的结果与潜水员在高压舱中补偿环境压力变化的能力。

材料和方法

该研究包括 35 名接受年度体检的专业潜水员。对所有受试者,首先在休息时测量鼓室内压,然后在用阻抗计进行瓦尔萨尔瓦动作后测量。然后进行功能测试(BFT)以评估潜水能力和咽鼓管的可通过性。它包括潜水员在高压舱中压缩和解压至 2.2ATA 压力 1 分钟。基于以前的研究结果,我们使用 ETF 测试的 20DaPa 截止点来预测咽鼓管的可通过性和成功的功能测试。

结果

在目前的研究中,24 名潜水员的 ETF 测试结果高于 20DaPa。3 名潜水员双耳 ETF 测试值低于 20DaPa,但他们均未在 BFT 中显示出困难。8 名潜水员一只耳朵的 ETF 值低于 20DaPa,另一只耳朵的 ETF 值高于 20DaPa。最后一组中的 7 名潜水员在 ETF 结果较差的耳朵中 BFT 出现困难。

结论

我们认为 ETF 测试可用于评估潜水能力,作为进行 BFT 之前的筛选方法,因为高于 20DaPa 的值可保证咽鼓管功能足以进行潜水活动。20DaPa 及以下的值不能明确预测 BFT 结果。ETF 测试的结果也可用于耳鼻喉科医生的常规工作,以评估中耳单侧疾病中的咽鼓管功能。