健康中国儿童呼吸纤毛的功能分析与评估。

Functional analysis and evaluation of respiratory cilia in healthy Chinese children.

机构信息

Department of Paediatrics and Adolescent Medicine, Queen Mary Hospital, HKSAR, China.

Department of Paediatrics and Adolescent Medicine, Duchess of Kent Children's Hospital, HKSAR, China.

出版信息

Respir Res. 2020 Oct 9;21(1):259. doi: 10.1186/s12931-020-01506-w.

Abstract

BACKGROUND

To aid in the diagnosis of Primary Ciliary Dyskinesia (PCD) and to evaluate the respiratory epithelium in respiratory disease, normal age-related reference ranges are needed for ciliary beat frequency (CBF), beat pattern and ultrastructure. Our aim was to establish reference ranges for healthy Chinese children.

METHODS

Ciliated epithelial samples were obtained from 135 healthy Chinese children aged below 18 years by brushing the inferior nasal turbinate. CBF and beat pattern were analysed from high speed video recordings. Epithelial integrity and ciliary ultrastructure were assessed using transmission electronic microscopy.

RESULTS

The mean CBF from 135 children studied was 10.1 Hz (95% CI 9.8 to 10.4). Approximately 20% (ranged 18.0-24.2%) of ciliated epithelial edges were found to have areas of dyskinetically beating cilia. Normal beat pattern was observed in ciliated epithelium from all subjects. We did not find any effect of exposure to second hand smoke on CBF in our subjects. Microtubular defects were found in 9.3% of all of the cilia counted in these children, while other ciliary ultrastructural defects were found in less than 3%.

CONCLUSIONS

We established the reference range for CBF, beat pattern and ultrastructure in healthy Chinese children. Using similar methodology, we found a lower overall mean CBF than previously obtained European values. This study highlights the need to establish normative data for ciliary function in different populations.

摘要

背景

为了辅助原发性纤毛运动障碍(PCD)的诊断,并评估呼吸道疾病中的呼吸道上皮细胞,我们需要建立正常的、与年龄相关的纤毛摆动频率(CBF)、摆动模式和超微结构参考范围。我们的目的是建立健康中国儿童的参考范围。

方法

通过刷取下鼻甲,从 135 名年龄在 18 岁以下的健康中国儿童中获得纤毛上皮样本。从高速视频记录中分析 CBF 和摆动模式。使用透射电子显微镜评估上皮完整性和纤毛超微结构。

结果

从 135 名研究儿童中得出的平均 CBF 为 10.1Hz(95%CI9.8-10.4)。大约 20%(范围为 18.0-24.2%)的纤毛上皮边缘被发现存在纤毛运动障碍的区域。所有受试者的纤毛上皮均观察到正常的摆动模式。我们未发现二手烟暴露对受试者 CBF 有任何影响。在这些儿童中计数的所有纤毛中,发现 9.3%存在微管缺陷,而其他纤毛超微结构缺陷则少于 3%。

结论

我们建立了健康中国儿童 CBF、摆动模式和超微结构的参考范围。使用类似的方法,我们发现总体平均 CBF 低于之前获得的欧洲数值。这项研究强调了在不同人群中建立正常纤毛功能数据的必要性。