The possibility of using two variants of the enzyme-linked fluorescent cofactor immunoassay for the determination of antibody binding constants has been demonstrated. The determination of binding constants for antibodies isolated by affinity chromatography techniques has been carried out. These techniques permit the isolation of fractions, differing in their affinity by 5-10 times, from the whole population of antibodies.
已经证明了使用酶联荧光辅因子免疫测定的两种变体来测定抗体结合常数的可能性。已经对通过亲和色谱技术分离的抗体的结合常数进行了测定。这些技术允许从整个抗体群体中分离出亲和力相差5至10倍的组分。