ORL Department Friedrichshain Clinic, Vivantes Hearing Center Berlin, Berlin, Germany.
Cochlear Deutschland GmbH & Co. KG, Hannover, Germany.
Int J Audiol. 2021 Jul;60(7):507-513. doi: 10.1080/14992027.2020.1839678. Epub 2020 Oct 30.
The goal of this study was the evaluation of a synthetic version of the Digits-in-Noise (DiN) in participants with normal hearing. Additionally, the basis characteristics of the DiN in CI recipients were investigated.
Twenty participants with normal hearing and 21 CI recipients with a Nucleus®-System ran two to three adaptive and up to five fixed measurements. Afterwards the discrimination function was measured with fixed signal-to-noise ratios.
All subjects were able to perform the DiN within three minutes per test run. The median speech reception threshold (SRT) for the NH was -8.1 dB, with a median steepness of 23%/dB. The median absolute test-retest difference in the NH group was 0.4 dB (range: 0 to 1.5 dB). In the CI group, the SRTs range from -6.6 to +12.4 dB with a median test-retest difference of 0.4 dB (range: 0 to 6.1 dB).
The synthetic DiN is a valuable complement of the audiometric test battery in CI recipients. The excellent applicability is also particularly helpful in poor performing CI recipients. With its small time exposure, it is a time- and cost-saving test, which could also be used at home via app to check the individual hearing success.
本研究旨在评估数字噪声测试(Digits-in-Noise,DiN)的合成版本在正常听力受试者中的应用。此外,还研究了 CI 受者 DiN 的基本特征。
20 名正常听力受试者和 21 名植入 Nucleus®系统的 CI 受者进行了 2 到 3 次自适应测试和最多 5 次固定测试。之后,使用固定的信噪比测量了辨别函数。
所有受试者都能在每次测试运行中在三分钟内完成 DiN 测试。NH 组的平均言语接受阈值(SRT)为-8.1dB,平均斜率为 23%/dB。NH 组的绝对测试-重测差异中位数为 0.4dB(范围:0 至 1.5dB)。在 CI 组中,SRT 范围为-6.6 至+12.4dB,测试-重测差异中位数为 0.4dB(范围:0 至 6.1dB)。
合成 DiN 是 CI 受者听力学测试组合的有价值补充。其出色的适用性在表现不佳的 CI 受者中特别有帮助。由于测试时间短,它是一种节省时间和成本的测试,也可以通过应用程序在家中使用,以检查个体的听力效果。