Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Anadolu University, 26470, Eskisehir, Turkey.
Department of Analytical Chemistry, Faculty of Pharmacy, Anadolu University, 26470, Eskisehir, Turkey.
Comb Chem High Throughput Screen. 2021;24(3):386-399. doi: 10.2174/1386207323999201110192558.
In the present study, a sensitive and selective liquid chromatographytandem mass spectrometry (LC-MS/MS) method was described for the determination of ceftiofur (CEF) in cow milk and pharmaceutical preparations. CEF is an antibiotic compound, which is commonly used in the treatment of animal diseases such as respiratory system, soft tissue, and foot infections, as well as postpartum acute puerperal metritis. One of the critical features of CEF is its prescription while breastfeeding cows; in accordance, its quantitative estimation is essential to assess its residual amounts.
In the method reported herein, after simple protein precipitation using acetonitrile, the pre-treated samples were introduced into an LC-MS/MS instrument equipped with a Chromolith® High-Resolution RP-18 series HPLC column (100 mm × 4.6 mm from Merck KGaA, Germany). Electrospray ionization was employed as the ionization source in the triple-quadrupole tandem mass spectrometer.
For the calibration method using solvent-based standards, LOQ was 3.038 ng/mL, 12.15 ng/mL, and LOD was 1.215 ng/mL and 6.076 ng/mL for ESI+ and ESI- modes, respectively. On the other hand, for the method of matrix-matched standards, LOQ was 1.701 ng/mL, 10.13 ng/mL, and LOD was 0.486 ng/mL and 5.929 ng/mL for ESI+ and ESI- modes, respectively as obtained from signal to noise ratio.
Applicability of both positive and negative ion modes was tested, and the analyte was detected via multiple reaction monitoring. The distorting effects of the milk matrix on the MS ionization and quantitation of CEF were overcome by using matrix-matched calibration for the first time.
本研究建立了一种灵敏、专属的液相色谱-串联质谱(LC-MS/MS)法,用于牛奶和药物制剂中头孢噻呋(CEF)的检测。CEF 是一种抗生素化合物,常用于治疗动物疾病,如呼吸系统、软组织和足部感染,以及产后急性产褥期子宫炎。CEF 的一个关键特点是在给奶牛开处方时使用;因此,定量估计其残留量至关重要。
在本报告的方法中,采用乙腈简单沉淀蛋白后,将预处理的样品引入配备 Chromolith®高分辨率 RP-18 系列 HPLC 柱(100mm×4.6mm,来自德国默克公司)的 LC-MS/MS 仪器中。电喷雾电离(ESI)作为三重四极杆串联质谱的离子源。
采用溶剂标准品的校准方法,ESI+和 ESI-模式的 LOQ 分别为 3.038ng/mL、12.15ng/mL 和 LOD 分别为 1.215ng/mL 和 6.076ng/mL。另一方面,采用基质匹配标准品的方法,ESI+和 ESI-模式的 LOQ 分别为 1.701ng/mL、10.13ng/mL 和 LOD 分别为 0.486ng/mL 和 5.929ng/mL,均为信噪比获得。