Postgraduate Programme in Environmental Health and Work, Faculty of Medicine, Federal University of Bahia, Salvador, Brazil.
Postgraduate Programme in Collective Health, Institute of Collective Health, Federal University of Bahia, Salvador, Brazil.
J Am Acad Audiol. 2021 Feb;32(2):116-121. doi: 10.1055/s-0040-1718931. Epub 2020 Dec 9.
This article investigates the validity of a smartphone-based audiometry for hearing screening to identify hearing loss in workers exposed to noise.
This is a validation study comparing hearing screening with the hearTest to conventional audiometry. The study population included all workers who attended the Brazilian Social Service of Industry to undergo periodic examinations. Sensitivity, specificity, the Youden index, and positive (PPV) and negative predictive values (NPV) for hearing screening obtained by the hearTest were estimated according to three definitions of hearing loss: any threshold greater than 25 dB hearing level (HL), the mean auditory thresholds for 0.5, 1, 2, and 4 kHz greater than 25 dB HL, and the mean thresholds for 3, 4, and 6 kHz greater than 25 dB HL. Note that 95% confidence intervals were calculated for all measurements.
A total of 232 workers participated in the study. Hearing screening with the hearTest presented good sensitivity (93.8%), specificity (83.9%), and Youden index (77.7%) values, a NPV (97.2%), and a low PPV (69.0%) for the identification of hearing loss defined as any auditory threshold greater than 25 dB HL. For the other definitions of hearing loss, we observed high specificity, PPV and NPV, as well as low sensitivity and Youden index.
The hearTest is an accurate hearing screening tool to identify hearing loss in workers exposed to noise, including those with noise-induced hearing loss, although it does not replace conventional audiometry.
本文旨在研究基于智能手机的听力筛查用于识别噪声暴露工人听力损失的有效性。
这是一项验证性研究,比较了 hearTest 听力筛查与传统听力测试的结果。研究对象包括所有参加巴西工业社会服务进行定期检查的工人。根据三种听力损失定义,即任何阈值大于 25dB 听力级(HL)、0.5、1、2 和 4kHz 的平均听阈大于 25dB HL、3、4 和 6kHz 的平均听阈大于 25dB HL,估算了 hearTest 听力筛查的敏感性、特异性、约登指数、阳性预测值(PPV)和阴性预测值(NPV)。请注意,所有测量值均计算了 95%置信区间。
共有 232 名工人参加了研究。使用 hearTest 进行听力筛查,对于任何阈值大于 25dB HL 的听力损失定义,其敏感性(93.8%)、特异性(83.9%)和约登指数(77.7%)、NPV(97.2%)和低 PPV(69.0%)都表现良好。对于其他听力损失定义,我们观察到高特异性、PPV 和 NPV,以及低敏感性和约登指数。
hearTest 是一种准确的听力筛查工具,可用于识别噪声暴露工人的听力损失,包括噪声性听力损失,但不能替代传统听力测试。