Suppr超能文献

正常犬跟骨/common 跟腱的超声弹性成像:初步结果。

Sonoelastography of Normal Canine Common Calcaneal Tendon: Preliminary Results.

机构信息

Department of Medicine, Faculty of Veterinary Medicine, University of Teramo, Piano D'Accio, Teramo, Italy.

出版信息

Vet Comp Orthop Traumatol. 2021 May;34(3):200-205. doi: 10.1055/s-0040-1721660. Epub 2020 Dec 10.

Abstract

Shear wave elastography (SWE) is a feasible and newly developed ultrasonographic technique which is able to assess elasticity of tissues. The aim of this work was to assess the feasibility of SWE on the normal canine common calcaneal tendon (CCT) evaluating the intra-operator repeatability and reproducibility of single measurements and stiffness of different anatomic CCT portions was examined. Tendons were first evaluated with B-mode ultrasound with a linear probe 8.5 to 10 MHz in longitudinal section with slight flexed tarsocrural joint and a gel-pad. Common calcaneal tendon was divided into three different anatomical regions. Shear wave elastography was performed in each region by two operators and quantitative evaluation (m/s and kPa) was performed on the most representative images. Region of interest (0.15 cm) was settled. Intraclass correlation coefficient (ICC) results were classified using the following scale: 0.00 to 0.20 = poor; 0.20 to 0.40 = fair; 0.40 to 075 = good; >0.75 = excellent. Ten adult dogs were enrolled. Intra-operator ICC values were >0.75 for both operators in every tendon portion. Inter-operator SWE ICC values for m/s measurements were 0.3, 0.61 and 0.61 for the enthesis, intermediate portion and the myotendinous junction respectively; for kPa measurements, values were respectively 0.3, 0.7 and 0.81. The three CCT portions were significantly different in stiffness (-value < 0.001 for both m/s and kPa measurements). These preliminary results provide evidence that SWE is potentially appliable to assess mechanical properties of canine CCT affected by tendinopathies.

摘要

剪切波弹性成像(SWE)是一种可行的新兴超声技术,能够评估组织的弹性。本研究旨在评估 SWE 在正常犬跟骨/common calcaneal tendon(CCT)上的可行性,评估单次测量的操作者内可重复性和再现性,以及不同解剖 CCT 部位的硬度。首先使用线性探头 8.5 至 10MHz 在轻度跖跗关节弯曲的情况下对跟腱进行 B 型超声检查,并用凝胶垫进行检查。将 common calcaneal tendon 分为三个不同的解剖区域。由两位操作人员在每个区域进行 SWE,并在最具代表性的图像上进行定量评估(m/s 和 kPa)。设定感兴趣区域(0.15cm)。使用以下标准对组内相关系数(ICC)结果进行分类:0.00 至 0.20=差;0.20 至 0.40=尚可;0.40 至 0.75=良好;>0.75=优秀。纳入 10 只成年犬。两位操作人员在每个肌腱部位的操作者内 ICC 值均>0.75。m/s 测量的操作者间 SWE ICC 值分别为 0.3、0.61 和 0.61,用于附着点、中间部分和肌-腱交界处;对于 kPa 测量,值分别为 0.3、0.7 和 0.81。三个 CCT 部位的硬度有显著差异(m/s 和 kPa 测量的 -值均<0.001)。这些初步结果表明 SWE 可能适用于评估受腱病影响的犬 CCT 的机械特性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验