Suppr超能文献

用于喂养早产儿的巴氏消毒人乳的最佳细菌学筛查试验截止值是多少?

What are Optimal Bacteriological Screening Test Cut-Offs for Pasteurized Donor Human Milk Intended for Feeding Preterm Infants?

机构信息

216919 Australian Red Cross Lifeblood, Australia.

Murdoch Children's Research Institute, Flemington Rd, Parkville, VIC, Australia.

出版信息

J Hum Lact. 2021 Feb;37(1):43-51. doi: 10.1177/0890334420981013. Epub 2020 Dec 22.

Abstract

BACKGROUND

Definitive criteria for microbial screening of pasteurized donor human milk are not well established and international recommendations vary.

AIMS

(1) To review pasteurized donor human milk batch discard due to failed microbial screening criteria at our milk bank (following United Kingdom National Institute of Clinical Excellence guidelines), and (2) to compare our known milk discard proportion with estimated milk discard proportions that would be required by other international milk bank guidelines.

METHODS

We reviewed our microbial screening results ( = 783) over 18-months (July 2018-December 2019) and compared our known milk discard proportion with estimated milk discard proportions using other international milk bank guidelines.

RESULTS

Of samples, = 50 (6.4%) failed pre-pasteurization screening, most commonly due to the presence of >10 CFU/mL in the pre-pasteurization sample ( = 30; 3.8%). Two (0.3%) samples failed post-pasteurization screening, with identified in both cases, resulting in total discard proportion of 6.7% ( = 52) of batches. Applying European Milk Bank Association recommended bacterial screening criteria, approximately 23.3% ( = 183) of milk batches would have been discarded.

CONCLUSIONS

Further research is required to justify the stringent European Milk Bank Association recommendations for pre-pasteurization discard criteria, although we believe that a post-pasteurization acceptance criterion of <1 CFU/mL is appropriate and aligns with international guidance. Further work is needed to understand pasteurized donor human milk microbiological safety risks, to better integrate screening criteria within current food standards regulation, and to consider risk-based assessment including the impact on availability and affordability.

摘要

背景

巴氏消毒供体人乳的微生物筛选标准尚未明确确立,国际建议也存在差异。

目的

(1)审查我们的母乳库中因微生物筛选标准不合格而丢弃的巴氏消毒供体人乳批次(遵循英国国家临床卓越研究所指南),(2)比较我们已知的牛奶丢弃比例与其他国际母乳库指南所需的估计牛奶丢弃比例。

方法

我们回顾了 18 个月(2018 年 7 月至 2019 年 12 月)的微生物筛选结果(=783),并使用其他国际母乳库指南比较了我们已知的牛奶丢弃比例与估计的牛奶丢弃比例。

结果

在样本中,=50(6.4%)在巴氏消毒前筛选中失败,最常见的原因是巴氏消毒前样本中存在>10 CFU/mL(=30;3.8%)。有两个(0.3%)样本在巴氏消毒后筛选中失败,两种情况下都发现了,导致总丢弃比例为 6.7%(=52)的批次。应用欧洲母乳库协会推荐的细菌筛选标准,约 23.3%(=183)的牛奶批次将被丢弃。

结论

需要进一步研究来证明欧洲母乳库协会对巴氏消毒前丢弃标准的严格建议是合理的,尽管我们认为 1 CFU/mL 以下的巴氏消毒后接受标准是合适的,并与国际指南一致。需要进一步研究来了解巴氏消毒供体人乳的微生物安全风险,更好地将筛选标准纳入当前的食品标准法规,并考虑基于风险的评估,包括对可用性和可负担性的影响。