Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, NY, USA.
Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, NY, USA.
Interv Neuroradiol. 2021 Aug;27(4):566-570. doi: 10.1177/1591019920982812. Epub 2020 Dec 26.
Radial loops are rare congenital radial artery anomalies that may pose a significant challenge to successful transradial neuroangiography. In this case series, we describe the anatomy and frequency of radial artery loops and provide a technique for successful navigation of this anatomic anomaly.
We reviewed our database of radial diagnostic or interventional neuroangiographic procedures to identify cases in which a radial loop was encountered during the procedure. The loop pattern, the presence of an associated recurrent radial artery branch, navigation technique, and procedure-related complications were recorded. A descriptive analysis was performed.
A total of 997 transradial approach procedures were performed over a 9-month period. A radial loop was identified in 10 (1.0%) patients. The average age was 68.6 ± 14.3 years. A microcatheter advanced over a microwire was used to navigate the loop and avoid entry into the recurrent branch. A diagnostic neuroangiographic procedure was performed successfully in 8 cases and an intervention was performed successfully in 1 case. A 360° loop was present in 2 of these cases. In each case, transradial access was performed successfully. In 1 other diagnostic case, transradial access was aborted, and the femoral artery was accessed to perform the procedure.
A radial loop was present in 1% of the cases in this series. Our technical results suggest that this anomaly should not be considered a contraindication to transradial neuroangiography because the procedure was successfully performed in most (9 of 10) cases using a microcatheter system to navigate the loop.
桡动脉环是罕见的先天性桡动脉异常,可能对成功的经桡动脉神经血管造影造成重大挑战。在本病例系列中,我们描述了桡动脉环的解剖结构和发生频率,并提供了一种成功导航这种解剖异常的技术。
我们回顾了我们的桡动脉诊断或介入神经血管造影程序数据库,以确定在程序中遇到桡动脉环的病例。记录了环的模式、是否存在相关的复发性桡动脉分支、导航技术和与程序相关的并发症。进行了描述性分析。
在 9 个月的时间里,共进行了 997 例经桡动脉入路的程序。在 10 例(1.0%)患者中发现了桡动脉环。平均年龄为 68.6±14.3 岁。使用微导管在微导丝上推进以导航环并避免进入复发性分支。成功完成 8 例诊断性神经血管造影程序,成功完成 1 例介入治疗。其中 2 例存在 360°环。在每个病例中,都成功进行了经桡动脉入路。在另一个诊断性病例中,经桡动脉入路被放弃,改用股动脉进行手术。
在本系列中的 1%的病例中存在桡动脉环。我们的技术结果表明,不应将这种异常视为经桡动脉神经血管造影的禁忌症,因为在大多数(10 例中的 9 例)病例中,使用微导管系统成功地对环进行了导航,从而成功地完成了该程序。