Suppr超能文献

不同类型扫描仪获取的 3D 图像准确性比较:系统评价。

Comparison of the Accuracy of 3D Images Obtained fromDifferent Types of Scanners: A Systematic Review.

机构信息

Division of Facial Abnormalities, Department of Maxillofacial Orthopedics and Orthodontics, Wroclaw Medical University, Wroclaw, Poland.

Faculty of Dentistry, Wroclaw Medical University, Wroclaw, Poland.

出版信息

J Healthc Eng. 2020 Dec 14;2020:8854204. doi: 10.1155/2020/8854204. eCollection 2020.

Abstract

INTRODUCTION

The purpose of this systematic review was to compare the accuracy of the three-dimensional images among different scanners, scanning techniques, and substrates. . Electronic databases (PubMed and Elsevier) were searched until March 2020. The systematic search was performed to identify the most precise method of obtaining a 3D image of the dentition.

RESULTS

Thirteen articles out of 221, considering the accuracy of 3D images, were selected. The main factors that are considered to have an influence on the precision are substrate type in the oral cavity, experience of the scanner's operator, direct vs. indirect scanning, and the reproducibility of the procedure.

CONCLUSION

Substrate type does have an impact on the overall accuracy of intraoral scans where dentin has the most and enamel the least accurately recorded dental structure. Experience of the operator has an influence on the accuracy, where more experienced operators and smaller scan sizes are made for more accurate scans. A conventional impression technique in a full-arch image provided the lowest deviation. The reproducibility of direct scanning was comparable to indirect scanning although a slight difference was noticeable (0.02 mm).

摘要

简介

本系统评价的目的是比较不同扫描仪、扫描技术和基底的三维图像的准确性。电子数据库(PubMed 和 Elsevier)搜索至 2020 年 3 月。系统搜索旨在确定获得牙齿三维图像的最精确方法。

结果

在考虑 3D 图像准确性的情况下,从 221 篇文章中选择了 13 篇。被认为对精度有影响的主要因素是口腔内的基底类型、扫描仪操作员的经验、直接扫描与间接扫描以及程序的可重复性。

结论

基底类型确实会影响口腔内扫描的整体准确性,其中牙本质记录的牙齿结构最不准确,而牙釉质最准确。操作员的经验会影响准确性,经验丰富的操作员和较小的扫描尺寸会进行更精确的扫描。全牙弓图像中的常规印模技术提供的偏差最小。直接扫描的可重复性与间接扫描相当,尽管有细微差别(0.02 毫米)。

相似文献

1
Comparison of the Accuracy of 3D Images Obtained fromDifferent Types of Scanners: A Systematic Review.
J Healthc Eng. 2020 Dec 14;2020:8854204. doi: 10.1155/2020/8854204. eCollection 2020.
2
Influence of operator experience, scanner type, and scan size on 3D scans.
J Prosthet Dent. 2021 Feb;125(2):294-299. doi: 10.1016/j.prosdent.2019.12.011. Epub 2020 Feb 27.
3
In vitro evaluation of the accuracy and precision of intraoral and extraoral complete-arch scans.
J Prosthet Dent. 2021 Nov;126(5):665-670. doi: 10.1016/j.prosdent.2020.08.017. Epub 2020 Oct 16.
4
Evaluation of the accuracy of digital impressions with different scanning strategies: An in vitro study.
J Dent. 2024 Dec;151:105433. doi: 10.1016/j.jdent.2024.105433. Epub 2024 Oct 28.
6
Evaluation of the accuracy of 2 digital intraoral scanners: A 3D analysis study.
J Prosthet Dent. 2021 Dec;126(6):787-792. doi: 10.1016/j.prosdent.2020.10.004. Epub 2020 Nov 7.
9
Evaluating the influence of palate scanning on the accuracy of complete-arch digital impressions-An in vitro study.
J Dent. 2024 Jun;145:105014. doi: 10.1016/j.jdent.2024.105014. Epub 2024 Apr 20.
10
A guide for maximizing the accuracy of intraoral digital scans. Part 1: Operator factors.
J Esthet Restor Dent. 2023 Jan;35(1):230-240. doi: 10.1111/jerd.12985. Epub 2022 Dec 7.

引用本文的文献

1
The production and materials of mouthguards: Conventional vs additive manufacturing - A systematic review.
Heliyon. 2024 Jul 8;10(14):e34294. doi: 10.1016/j.heliyon.2024.e34294. eCollection 2024 Jul 30.
8
Digital intraoral scanner devices: a validation study based on common evaluation criteria.
BMC Oral Health. 2022 Apr 26;22(1):140. doi: 10.1186/s12903-022-02176-4.

本文引用的文献

1
Accuracy of Digital and Conventional Full-Arch Impressions in Patients: An Update.
J Clin Med. 2020 Mar 4;9(3):688. doi: 10.3390/jcm9030688.
2
Influence of operator experience, scanner type, and scan size on 3D scans.
J Prosthet Dent. 2021 Feb;125(2):294-299. doi: 10.1016/j.prosdent.2019.12.011. Epub 2020 Feb 27.
3
An in vitro 3D evaluation of the accuracy of 4 intraoral optical scanners on a 6-implant model.
J Prosthet Dent. 2020 Dec;124(6):748-754. doi: 10.1016/j.prosdent.2019.10.013. Epub 2020 Feb 7.
5
Trueness and precision of intraoral scanners in the maxillary dental arch: an in vivo analysis.
Sci Rep. 2020 Jan 24;10(1):1172. doi: 10.1038/s41598-020-58075-7.
6
The effect different substrates have on the trueness and precision of eight different intraoral scanners.
J Esthet Restor Dent. 2020 Mar;32(2):204-218. doi: 10.1111/jerd.12528. Epub 2019 Sep 30.
7
Accuracy and practicality of intraoral scanner in dentistry: A literature review.
J Prosthodont Res. 2020 Apr;64(2):109-113. doi: 10.1016/j.jpor.2019.07.010. Epub 2019 Aug 30.
8
Effect of scan substrates on accuracy of 7 intraoral digital impression systems using human maxilla model.
Orthod Craniofac Res. 2019 May;22 Suppl 1:168-174. doi: 10.1111/ocr.12273.
9
Feasibility of using an intraoral scanner for a complete-arch digital scan.
J Prosthet Dent. 2019 May;121(5):803-810. doi: 10.1016/j.prosdent.2018.07.014. Epub 2018 Dec 28.
10
Reproducibility of an intraoral scanner: A comparison between in-vivo and ex-vivo scans.
Am J Orthod Dentofacial Orthop. 2018 Aug;154(2):305-310. doi: 10.1016/j.ajodo.2017.09.022.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验