Abstract

BACKGROUND

Nasoalveolar molding is a nonsurgical modality for the treatment of cleft lip and palate that uses an intraoral splint to align the palatal shelves. Repeated impressions are needed for splint modification, each carrying risk of airway obstruction. Computer-aided design and manufacturing (CAD/CAM) has the ability to simplify the process. As a precursor to CAD/CAM splint fabrication, a proof-of-concept study was conducted to compare three-dimensional splints printed from alginate impressions versus digital scans. We hypothesized that intraoral digital scanning would compare favorably to alginate impressions for palate registration and subsequent splint manufacture, with decreased production times.

METHODS

Alginate and digital impressions were taken from 25 healthy teenage volunteers. Digital impressions were performed with a commercially available intraoral scanner. Plaster casts made from alginate impressions were converted to Standard Triangle Language files. Patient-specific matched scans were evaluated for total surface area with the concordance correlation coefficient. Acrylic palatal splints were three-dimensionally printed from inverse digital molds. Subjective appliance fit was assessed using a five-point scale.

RESULTS

A total of 23 participants were included. Most subjects preferred digital impression acquisition. Impression methods showed moderate agreement (concordance correlation coefficient 0.93). Subjects rated splints from digital impressions as having a more precise fit (4.4 versus 3.9). The digital approach decreased impression phase time by over 10-fold and overall production time by 28%.

CONCLUSIONS

CAD/CAM has evolved extensively over the past two decades and is now commonplace in medicine. However, its utility in cleft patients has not been fully realized. This pilot study demonstrated that CAD/CAM technologies may prove useful in patients requiring intraoral splints.

摘要

背景

鼻腔内矫正术是一种治疗唇腭裂的非手术方法,它使用口腔内夹板来对齐腭骨。夹板的修改需要多次印模,每次都有气道阻塞的风险。计算机辅助设计和制造(CAD/CAM)有能力简化这个过程。作为 CAD/CAM 夹板制造的前期工作,进行了一项概念验证研究,比较了从藻酸盐印模和数字扫描打印的三维夹板。我们假设,口腔内数字扫描在腭部注册和随后的夹板制造方面将优于藻酸盐印模,生产时间也会缩短。

方法

从 25 名健康的青少年志愿者中采集藻酸盐和数字印模。数字印模是用商业上可用的口腔内扫描仪进行的。藻酸盐印模制成的石膏模型被转换为标准三角语言文件。使用一致性相关系数评估患者特定的匹配扫描的总表面积。从反向数字模具中三维打印丙烯酸腭夹板。使用五点量表评估器械的适配度。

结果

共有 23 名参与者被纳入。大多数受试者更喜欢数字印模采集。印模方法显示出中等程度的一致性(一致性相关系数为 0.93)。受试者认为数字印模的夹板更贴合(4.4 分对 3.9 分)。数字方法使印模阶段的时间减少了 10 多倍,总生产时间减少了 28%。

结论

CAD/CAM 在过去二十年中得到了广泛的发展,现在在医学中已经很常见。然而,它在唇腭裂患者中的应用尚未得到充分实现。这项初步研究表明,CAD/CAM 技术可能对需要口腔内夹板的患者有用。