Department for Trauma and Reconstructive Surgery, BG Klinik, University of Tübingen, Tübingen, Germany.
Center for Musculoskeletal Surgery, Charité - University Medical Center Berlin, Berlin, Germany.
Int Orthop. 2021 Aug;45(8):2001-2005. doi: 10.1007/s00264-020-04931-0. Epub 2021 Jan 20.
The original Caton-Deschamps index (oCDI) detects functional patella height. It cannot be used in knees with an implanted endoprosthesis. The "modified Caton-Deschamps index" (mCDI) for knee arthroplasty can miss pseudo-patella-infera (PPI), which is common after TKA. A derivate of the oCDI could be a simple analogue to the index published in 1982 using a modified tibial reference point at the anterior proximal point of the inlay, which can indirectly be located on the lateral knee radiograph. It was the aim of this study to determine the intra- and inter-rater agreement of a derived Caton-Deschamps index (dCDI) for knee arthroplasty. We hypothesized that the derived Caton-Deschamps index (dCDI) is a reliable radiological measure for patella height in knee arthroplasty.
Several patella height indices were measured by three independent raters in two passes. The second pass was performed after 6 weeks in random order. Intra- and inter-observer agreements were determined and analyzed using the intraclass correlation coefficient (ICC). For radiographic evaluation, digital lateral radiographs of 150 knees before and after primary TKA were used.
We found high interrater reliability for all analyzed indices. We found the highest agreements for the ISI preop (ICC = 0.914) and postop (ICC = 0.920), respectively. We also found very good intra-rater reliability for the CDI (ICCpreop = 0.954), dCDI (ICCpostop = 0.945), ISI (ICCpreop = 0.960; ICCpostop=0.940) and BPI (ICCpreop = 0.969; ICCpostop = 0.955). Fourteen cases (9.3%) with insignificant PPI were found.
The derived Caton-Deschamps index (dCDI) can easily be used in knee arthroplasty and demonstrated high intra- and interrater agreement, which was similar to other commonly used and established patella height indices.
原始的 Caton-Deschamps 指数(oCDI)可检测功能髌骨高度。它不能用于植入假体的膝关节。用于膝关节置换的“改良的 Caton-Deschamps 指数”(mCDI)可能会错过 TKA 后常见的假性髌骨下(PPI)。oCDI 的一个衍生指数可以是 1982 年发表的指数的简单模拟,使用胫骨内植入物前缘的近端点作为改良的参考点,该点可以在外侧膝关节 X 线片上间接定位。本研究旨在确定改良的 Caton-Deschamps 指数(dCDI)在膝关节置换中的内部和内部观察者之间的一致性。我们假设改良的 Caton-Deschamps 指数(dCDI)是膝关节置换中髌骨高度的可靠影像学测量方法。
三名独立的观察者进行了两次测量,以确定多个髌骨高度指数。第二次测量是在 6 周后随机进行的。使用组内相关系数(ICC)来确定和分析内部和观察者之间的一致性。对于放射学评估,使用了 150 例初次 TKA 前后的数字外侧 X 线片。
我们发现所有分析的指数都具有很高的观察者间可靠性。我们发现术前 ISI(ICC = 0.914)和术后 ISI(ICC = 0.920)的一致性最高。我们还发现 CDI(ICCpreop = 0.954)、dCDI(ICCpostop = 0.945)、ISI(ICCpreop = 0.960;ICCpostop = 0.940)和 BPI(ICCpreop = 0.969;ICCpostop = 0.955)的内部观察者可靠性非常高。发现有 14 例(9.3%)无明显 PPI 的病例。
改良的 Caton-Deschamps 指数(dCDI)可轻松用于膝关节置换,并且具有较高的内部和观察者间一致性,与其他常用且已建立的髌骨高度指数相似。