Suppr超能文献

IDEXX Legiolert 方法与其他革兰氏阴性菌和水源性病原体的交叉反应会导致假阳性检测结果。

Cross-reactivity of the IDEXX Legiolert method with other Gram-negative bacteria and waterborne pathogens leads to false-positive assay results.

机构信息

Special Pathogens Laboratory, Pittsburgh, PA, USA.

Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA, USA.

出版信息

Lett Appl Microbiol. 2021 Jun;72(6):750-756. doi: 10.1111/lam.13469. Epub 2021 Mar 15.

Abstract

Legionella species are the causative agent of Legionnaires' disease, a potentially fatal bacterial pneumonia. New regulations and standards have prioritized the development of water safety plans to minimize the growth and spread of Legionella species in buildings. To determine the presence and type of Legionella in a water system, microbiological culturing is the gold standard method. However, recently new methodologies have been developed that claim to be sensitive and specific for Legionella at the genus or L. pneumophila at the species level. Published and anecdotal reports suggest that one of these newer culture-based, enzyme-substrate methods, the IDEXX Legiolert test, may exhibit false positivity with other microbes common to water sources. We experimentally evaluated the IDEXX Legiolert method using these other waterborne bacteria including Elizabethkingia meningoseptica, Pseudomonas aeruginosa, Proteus mirabilis and Serratia marcescens at real-world environmental concentrations. We saw false-positive results for the Legiolert test with several of these organisms, at sample concentrations as low as 60 CFU per ml. False-positive Legionella results can trigger costly remediation and water-use restrictions, that may be implemented while waiting for additional, confirmatory microbiological testing that could, in this case, yield no L. pneumophila.

摘要

军团菌属是军团病的病原体,一种潜在致命的细菌性肺炎。新的法规和标准优先制定了水安全计划,以尽量减少军团菌属在建筑物中的生长和传播。为了确定水中军团菌属的存在和类型,微生物培养是金标准方法。然而,最近开发了一些新的方法,据称在属水平上对军团菌属或种水平上的嗜肺军团菌属具有敏感性和特异性。已发表的和传闻的报告表明,这些基于培养的新型酶底物方法之一,IDEXX Legiolert 测试,可能与水源中常见的其他微生物发生假阳性。我们使用这些其他水生细菌(包括脑膜败血伊丽莎白菌、铜绿假单胞菌、奇异变形杆菌和粘质沙雷氏菌),在真实环境浓度下,对 IDEXX Legiolert 方法进行了实验评估。我们看到该测试对几种生物体的假阳性结果,在样本浓度低至每毫升 60 CFU 时就出现了假阳性。假阳性的军团菌结果可能会引发昂贵的修复和用水限制,可能会在等待其他确认性微生物测试期间实施,而在这种情况下,可能不会产生嗜肺军团菌属。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验