全膝关节置换中的塑料:从加工到性能

Plastics in Total Knee Replacement: Processing to Performance.

作者信息

Cheppalli Naga, Metikala Sreenivasulu, Albertson Benjamin S, Yaw Kenneth

机构信息

Orthopaedics, Veteran Affairs (VA) Hospital/University of New Mexico Hospital, Albuquerque, USA.

Orthopaedics, Virginia Commonwealth University Health System, Richmond, USA.

出版信息

Cureus. 2021 Jan 28;13(1):e12969. doi: 10.7759/cureus.12969.


DOI:10.7759/cureus.12969
PMID:33654631
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC7913782/
Abstract

Polyethylene (PE) is the key component of total knee replacement (TKR). The wear of polyethylene, a common cause of revision surgeries, depends on multiple factors. The mechanical properties, wear characteristics, and oxidative resistance of PE can be manipulated by the techniques of processing, sterilization, and packaging methods. This article describes the making of conventional and cross-linked poly, packaging, sterilization, processing techniques, and a summary of commercially available plastics and their rationale in TKR including the latest advances.

摘要

聚乙烯(PE)是全膝关节置换术(TKR)的关键部件。聚乙烯磨损是翻修手术的常见原因,其磨损取决于多种因素。通过加工、灭菌和包装方法等技术,可以控制PE的机械性能、磨损特性和抗氧化性。本文介绍了传统聚乙烯和交联聚乙烯的制造、包装、灭菌、加工技术,以及市售塑料的概述及其在TKR中的基本原理,包括最新进展。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f3d9/7913782/bfb7749e14ae/cureus-0013-00000012969-i02.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f3d9/7913782/5154bdacbdf3/cureus-0013-00000012969-i01.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f3d9/7913782/bfb7749e14ae/cureus-0013-00000012969-i02.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f3d9/7913782/5154bdacbdf3/cureus-0013-00000012969-i01.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f3d9/7913782/bfb7749e14ae/cureus-0013-00000012969-i02.jpg

相似文献

[1]
Plastics in Total Knee Replacement: Processing to Performance.

Cureus. 2021-1-28

[2]
Highly cross-linked polyethylene may not have an advantage in total knee arthroplasty.

HSS J. 2013-10

[3]
[Current knowledge on the effect of technology and sterilization on the structure, properties and longevity of UHMWPE in total joint replacement].

Acta Chir Orthop Traumatol Cech. 2012

[4]
How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study.

Clin Orthop Relat Res. 2016-8

[5]
[Innovative materials in orthopaedics: the crosslinked polyethylene (XPE)].

Ann Ig. 2011

[6]
The use of highly crosslinked polyethylene in total knee arthroplasty.

Bone Joint J. 2017-8

[7]
Does vitamin E-stabilized ultrahigh-molecular-weight polyethylene address concerns of cross-linked polyethylene in total knee arthroplasty?

J Arthroplasty. 2011-12-5

[8]
Vitamin E stabilised polyethylene for total knee arthroplasty evaluated under highly demanding activities wear simulation.

Acta Biomater. 2017-1-15

[9]
Sterilization and polyethylene wear: clinical studies to support laboratory data.

J Bone Joint Surg Am. 2004-5

[10]
Early Experience with Vitamin E Antioxidant-Infused Highly Cross-Linked Polyethylene Inserts in Primary Total Knee Arthroplasty.

Surg Technol Int. 2016-10-26

引用本文的文献

[1]
Recent Advances in PEEK for Biomedical Applications: A Comprehensive Review of Material Properties, Processing, and Additive Manufacturing.

Polymers (Basel). 2025-7-17

[2]
Radiopacity Enhancements in Polymeric Implant Biomaterials: A Comprehensive Literature Review.

ACS Biomater Sci Eng. 2024-3-11

[3]
Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up.

Knee Surg Sports Traumatol Arthrosc. 2023-3

[4]
Early migration of a medially stabilized total knee arthroplasty : a radiostereometric analysis study up to two years.

Bone Jt Open. 2021-9

本文引用的文献

[1]
Carbon Nanotubes and Graphene as Nanoreinforcements in Metallic Biomaterials: a Review.

Adv Biosyst. 2019-3

[2]
Early failure of sequentially annealed polyethylene in total knee arthroplasty.

Arthroplast Today. 2020-1-9

[3]
Conventional Versus Highly Cross-Linked Polyethylene in Primary Total Knee Replacement: A Comparison of Revision Rates Using Data from the National Joint Registry for England, Wales, and Northern Ireland.

J Bone Joint Surg Am. 2020-1-15

[4]
Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature.

Int Orthop. 2018-11-23

[5]
Polyethylene in total knee arthroplasty: Where are we now?

J Orthop Surg (Hong Kong). 2018

[6]
Strain and damage-sensing performance of biocompatible smart CNT/UHMWPE nanocomposites.

Mater Sci Eng C Mater Biol Appl. 2018-7-29

[7]
Five cases of tibial post fracture in posterior stabilized total knee arthroplasty using Prolong highly cross-linked polyethylene.

Knee. 2018-8

[8]
Early Fracture of a Vitamin-E-Infused, Highly Cross-Linked Polyethylene Liner After Total Hip Arthroplasty: A Case Report.

JBJS Case Connect. 2015

[9]
Is Cross-Linked Polyethylene an Improvement Over Conventional Ultra-High Molecular Weight Polyethylene in Total Knee Arthroplasty?

J Arthroplasty. 2017-10-10

[10]
Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

Clin Orthop Relat Res. 2017-12