在3T场强下使用MEGA-PRESS序列同时测量对视觉刺激的血氧水平依赖(BOLD)效应和代谢变化。

Simultaneous Measurement of the BOLD Effect and Metabolic Changes in Response to Visual Stimulation Using the MEGA-PRESS Sequence at 3 T.

作者信息

Dwyer Gerard Eric, Craven Alexander R, Bereśniewicz Justyna, Kazimierczak Katarzyna, Ersland Lars, Hugdahl Kenneth, Grüner Renate

机构信息

Department of Biological and Medical Psychology, University of Bergen, Bergen, Norway.

NORMENT Centre of Excellence, Haukeland University Hospital, Bergen, Norway.

出版信息

Front Hum Neurosci. 2021 Mar 24;15:644079. doi: 10.3389/fnhum.2021.644079. eCollection 2021.

Abstract

The blood oxygen level dependent (BOLD) effect that provides the contrast in functional magnetic resonance imaging (fMRI) has been demonstrated to affect the linewidth of spectral peaks as measured with magnetic resonance spectroscopy (MRS) and through this, may be used as an indirect measure of cerebral blood flow related to neural activity. By acquiring MR-spectra interleaved with frames without water suppression, it may be possible to image the BOLD effect and associated metabolic changes simultaneously through changes in the linewidth of the unsuppressed water peak. The purpose of this study was to implement this approach with the MEGA-PRESS sequence, widely considered to be the standard sequence for quantitative measurement of GABA at field strengths of 3 T and lower, to observe how changes in both glutamate (measured as Glx) and GABA levels may relate to changes due to the BOLD effect. MR-spectra and fMRI were acquired from the occipital cortex (OCC) of 20 healthy participants whilst undergoing intrascanner visual stimulation in the form of a red and black radial checkerboard, alternating at 8 Hz, in 90 s blocks comprising 30 s of visual stimulation followed by 60 s of rest. Results show very strong agreement between the changes in the linewidth of the unsuppressed water signal and the canonical haemodynamic response function as well as a strong, negative, but not statistically significant, correlation with the Glx signal as measured from the OFF spectra in MEGA-PRESS pairs. Findings from this experiment suggest that the unsuppressed water signal provides a reliable measure of the BOLD effect and that correlations with associated changes in GABA and Glx levels may also be measured. However, discrepancies between metabolite levels as measured from the difference and OFF spectra raise questions regarding the reliability of the respective methods.

摘要

功能磁共振成像(fMRI)中提供对比度的血氧水平依赖(BOLD)效应已被证明会影响磁共振波谱(MRS)测量的光谱峰线宽,并且通过这种方式,可作为与神经活动相关的脑血流量的间接测量指标。通过采集与无水抑制的帧交错的磁共振波谱,有可能通过未抑制水峰的线宽变化同时成像BOLD效应和相关的代谢变化。本研究的目的是使用MEGA - PRESS序列实施这种方法,MEGA - PRESS序列被广泛认为是在3T及更低场强下定量测量GABA的标准序列,以观察谷氨酸(以Glx测量)和GABA水平的变化如何与BOLD效应引起的变化相关。在20名健康参与者的枕叶皮质(OCC)进行磁共振波谱和fMRI采集,同时在扫描仪内以红色和黑色径向棋盘格的形式进行视觉刺激,以8Hz交替,在90秒的时间段内,包括30秒的视觉刺激,随后是60秒的休息。结果显示,未抑制水信号的线宽变化与典型血液动力学反应函数之间具有非常强的一致性,并且与MEGA - PRESS对中从OFF谱测量的Glx信号具有强烈的负相关,但无统计学意义。该实验的结果表明,未抑制水信号提供了BOLD效应的可靠测量指标,并且还可以测量与GABA和Glx水平相关变化的相关性。然而,从差异谱和OFF谱测量的代谢物水平之间的差异引发了关于各自方法可靠性的问题。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5e83/8024522/c909b0c8fdb7/fnhum-15-644079-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验