Bharati Vidyapeeth Dental College, Pune, India.
Folia Med (Plovdiv). 2021 Apr 30;63(2):253-263. doi: 10.3897/folmed.63.e52892.
To study the skeletal, dental effects and evaluate the soft tissue changes with PowerScope-fixed functional appliance in class II malocclusion.
This clinical study was carried out where a total of 10 growing (CVMS 3 and 4) Class II Division 1 malocclusion patients, indicated for treatment with fixed functional appliance were allocated based on specific inclusion criteria. PowerScope (American Orthodontics) was used as the fixed functional appliance. Skeletal, dental and soft tissue effects of the appliance with various angular and linear parameters on a digital lateral cephalogram were evaluated for all 10 participants. Records were collected before the insertion of PowerScope appliance (T0) and after 5 months, during the appliance removal (T1). All participants were treated with 0.018"×0.025" MBT (3M Unitek) prescription. Statistical analysis was performed using a paired t-test to compare individual mean changes for each treatment category.
Statistically significant changes were seen in skeletal parameters such as forward positioning of the mandible with an increase in SNB angle and N perpendicular-Pogonion distance, the class II jaw base relationship improved with reduction in ANB angle and Wits appraisal. Significant changes were observed in dental parameters such as forward positioning of mandibular incisors, maxillary molar distalization and intrusion with reduction in overbite and overjet respectively. In the soft tissue, a significant improvement in facial profile was seen due to an increase in labiomental angle.
The results of this study have shown that statistically significant changes in skeletal, dental and soft tissue parameters.
研究 PowerScope 固定功能矫治器对安氏Ⅱ类 1 分类错(牙合)畸形的骨骼、牙齿影响,并评估软组织变化。
本临床研究共纳入 10 名生长发育期(CVMS 3 和 4)安氏Ⅱ类 1 分类错(牙合)畸形患者,根据具体纳入标准,将其分为固定功能矫治器治疗组。采用 PowerScope(美国 Orthodontics)固定功能矫治器。对 10 名患者的数字侧位头颅侧位片进行各种角度和线性参数的骨骼、牙齿和软组织影响评估。所有参与者在插入 PowerScope 矫治器前(T0)和矫治器拆除时(T1),即 5 个月后,记录他们的口腔情况。所有参与者均采用 0.018"×0.025"MBT(3M Unitek)矫治器。使用配对 t 检验对每个治疗类别进行个体平均变化比较进行统计分析。
骨骼参数方面,下颌明显向前移位,SNB 角和 N 垂直点-颏顶点距离增加,Ⅱ类颌骨关系改善,ANB 角和 Wits 评价减小;牙齿参数方面,下颌切牙明显向前移位,上颌磨牙远中移动和内收,覆(牙合)和覆盖分别减小;软组织方面,由于唇颏角增加,面型得到显著改善。
本研究结果表明,PowerScope 固定功能矫治器对骨骼、牙齿和软组织参数均有显著的改善作用。