J Chromatogr B Analyt Technol Biomed Life Sci. 2021 Jun 1;1174:122716. doi: 10.1016/j.jchromb.2021.122716. Epub 2021 Apr 21.
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been increasingly used to measure steroids in human saliva. We studied the performance of a conventional LC-MS/MS for measuring dehydroepiandrosterone (DHEA), testosterone and progesterone in human saliva. These three steroids were co-extracted by liquid-liquid extraction and derivatized. Derivatives were resolved on a C18 column and quantified using an LC-MS/MS (AB Sciex API 2000) instrument. The assay's limits of quantification were 0.03 ng/mL for all three steroids. Inter-assay coefficients of variation were 16.6-18.8% (DHEA), 12.0-15.8% (testosterone), and 12.7-19.3% (progesterone). Assay linearity analysis showed R of 0.9926, 0.9750 and 0.9949 for DHEA, testosterone and progesterone, respectively. No carry-over between samplings was observed. An ion-enhancement effect of 11.6% for DHEA determination and ion-suppression effects of 13.9% and 20.7% for analysis of progesterone and testosterone, respectively, were determined. No interferences by 9 steroid analogs were detected. Spiked recoveries were 85.5% (DHEA), 86.5% (testosterone), and 92.6% (progesterone). Comparison with laboratory developed test (LDT)-LC-MS/MS methods by other New York State Department of Health certified laboratories revealed R = 0.9425 (DHEA, LC-MS/MS = 1.0267 LDT + 21.989), R = 0.9849 (testosterone, LC-MS/MS = 0.9447 LDT + 9.8037), and R = 0.9736 (progesterone, LC-MS/MS = 1.1196 LDT + 0.0985). Reference intervals for the 3 steroids in saliva for young males and females were estimated. Results of intra-individual salivary progesterone analysis indicated that caution should be exercised when using progesterone concentrations in predicting ovulation for females who are under treatment with birth control pills/devices or has body a weight of > 90 kg.
液相色谱-串联质谱法(LC-MS/MS)已被越来越多地用于测量人唾液中的类固醇。我们研究了一种常规 LC-MS/MS 测量人唾液中脱氢表雄酮(DHEA)、睾酮和孕酮的性能。这三种类固醇通过液液萃取和衍生化共同提取。衍生产物在 C18 柱上分离,并使用 LC-MS/MS(AB Sciex API 2000)仪器定量。所有三种类固醇的定量下限均为 0.03ng/mL。批内变异系数为 16.6-18.8%(DHEA)、12.0-15.8%(睾酮)和 12.7-19.3%(孕酮)。分析线性度分析显示,DHEA、睾酮和孕酮的 R 值分别为 0.9926、0.9750 和 0.9949。未观察到采样之间的交叉污染。DHEA 测定的离子增强效应为 11.6%,孕酮和睾酮分析的离子抑制效应分别为 13.9%和 20.7%。未检测到 9 种类固醇类似物的干扰。DHEA 的加标回收率为 85.5%,睾酮为 86.5%,孕酮为 92.6%。与纽约州卫生部认证实验室开发的实验室测试(LDT)-LC-MS/MS 方法的比较显示,R=0.9425(DHEA,LC-MS/MS=1.0267 LDT+21.989),R=0.9849(睾酮,LC-MS/MS=0.9447 LDT+9.8037),和 R=0.9736(孕酮,LC-MS/MS=1.1196 LDT+0.0985)。估计了年轻人唾液中这 3 种类固醇的参考区间。个体内唾液孕酮分析结果表明,对于正在服用避孕药/器具或体重>90kg 的女性,在预测排卵时应谨慎使用孕酮浓度。