Suppr超能文献

使用T1加权容积采集对正常犬眼进行磁共振成像。

Magnetic resonance imaging of the normal canine eye using a T1-weighted volumetric acquisition.

作者信息

Manchip Katherine Edith Leonora, Sansom Philip George, Donaldson David, Warren-Smith Chris

机构信息

South Devon Referrals, Devon, UK.

Department of Mathematics, University of Exeter, Exeter, UK.

出版信息

Vet Rec. 2021 Oct;189(8):e505. doi: 10.1002/vetr.505. Epub 2021 May 21.

Abstract

PURPOSE

MRI is becoming increasingly available within the veterinary profession, and eyes are frequently included as part of a cranial study. The advantages of volumetric imaging are numerous, when compared to traditional two-dimensional imaging, and could be utilised within the veterinary setting. This report describing the normal MRI appearance of the canine eye, aimed to establish a standard reference range on a T1w volumetric acquisition.

METHOD

This study retrospectively assessed 62 eyes from 31 dogs that had undergone MRI at the Small Animal Hospital, Langford Vets, University of Bristol between 2016 and 2018 using a standardised MRI protocol. Dogs were excluded if they had presented with any reported ocular or orbital abnormalities. Measurements were performed from the 3D T1w volumetric sequence by a single observer using a previously published technique.

RESULTS

Mean axial globe length was 2.13 cm and equatorial width 2.16 cm. Mean anteroposterior depth of the anterior chamber was 0.40 cm and 0.97 cm for the vitreous chamber. The mean anteroposterior and equatorial distance of the lens was 0.75 cm and 1.15 cm, respectively. Mean optic nerve width was 0.15 cm, and the mean width of the entire optic nerve sheath was 0.43 cm. Statistically significant relationships were noted between age and axial globe length and both lens dimensions. Highly significant relationships were noted between all variables, except lens dimensions and body weight Conclusion: This study provides reference values to assist in the interpretation of ocular structures during MRI on a T1w volumetric acquisition.

摘要

目的

磁共振成像(MRI)在兽医行业中越来越普及,眼部检查经常作为颅脑检查的一部分。与传统二维成像相比,容积成像具有诸多优势,可应用于兽医领域。本报告描述了犬眼的正常MRI表现,旨在建立T1加权容积采集的标准参考范围。

方法

本研究回顾性评估了2016年至2018年间在布里斯托大学朗福德兽医小动物医院接受MRI检查的31只犬的62只眼睛,采用标准化MRI方案。如果犬有任何报告的眼部或眼眶异常,则将其排除。由一名观察者使用先前发表的技术从3D T1加权容积序列中进行测量。

结果

平均眼轴长度为2.13厘米,赤道宽度为2.16厘米。前房平均前后深度为0.40厘米,玻璃体腔为0.97厘米。晶状体的平均前后距离和赤道距离分别为0.75厘米和1.15厘米。视神经平均宽度为0.15厘米,整个视神经鞘的平均宽度为0.43厘米。年龄与眼轴长度以及晶状体的两个维度之间存在统计学上的显著关系。除晶状体维度与体重外,所有变量之间均存在高度显著关系。结论:本研究提供了参考值,有助于在T1加权容积采集的MRI过程中解释眼部结构。