de Campos Azevedo Clara Isabel, Leiria Pires Gago Ângelo Ana Catarina, Quental Carlos, Gonçalves Sérgio, Folgado João, Ferreira Nuno, Sevivas Nuno
Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Campus de Gualtar, Braga, Portugal.
ICVS/3B's - PT Government Associate Laboratory, Braga/Guimarães, Portugal.
JSES Int. 2021 Mar 29;5(3):439-446. doi: 10.1016/j.jseint.2021.01.016. eCollection 2021 May.
The proximal fascia lata (FL) graft construct used for arthroscopic superior capsule reconstruction (ASCR) is openly harvested, whereas the mid-thigh FL graft construct is minimally invasively harvested. The purpose of the current study was to compare the biomechanical properties of proximal thigh and mid-thigh-harvested FL graft constructs used for ASCR. The hypothesis was that, despite the different morphological characteristics of the proximal thigh and mid-thigh FL graft constructs used for ASCR, their biomechanical properties would not significantly differ. This information may assist orthopedic surgeons in the choice of the harvest location, technique, and type of graft construct for ASCR.
Forty FL specimens, 20 proximal thigh and 20 mid-thigh, were harvested from the lateral thighs of 10 fresh human cadavers (6 male, 4 female; average age, 58.60 ± 17.20 years). The thickness of each 2-layered proximal thigh and 6-layered mid-thigh FL graft construct was measured. Each construct was mechanically tested in the longitudinal direction, and the stiffness and Young's modulus were computed. Data were compared by Welch's independent t-test and analysis of variance, and statistical significance was set at < .05.
The average thickness of the proximal thigh FL graft construct (7.17 ± 1.97 mm) was significantly higher than that of the mid-thigh (5.54 ± 1.37 mm) [F (1,32) = 7.333, = .011]. The average Young's modulus of the proximal thigh and mid-thigh graft constructs was 32.85 ± 19.54 MPa (range, 7.94 - 75.14 MPa; 95% confidence interval [CI], 23.71 - 42.99) and 44.02 ± 31.29 MPa (range, 12.53 -120.33 MPa; 95% CI, 29.38 - 58.66), respectively. The average stiffness of the proximal thigh and mid-thigh graft constructs was 488.96 ± 267.80 N/mm (range, 152.96 - 1086.49 N/mm; 95% CI, 363.63 - 614.30) and 562.39 ± 294.76 N/mm (range, 77.46 - 1229.68 N/mm; 95% CI, 424.44 - 700.34), respectively. There was no significant difference in the average Young's modulus or stiffness between the proximal thigh and mid-thigh graft constructs ( = .185 and = .415, respectively).
Despite the different morphological characteristics of the proximal thigh and mid-thigh FL graft constructs used for ASCR, their Young's modulus and stiffness did not significantly differ.
用于关节镜下上盂唇重建(ASCR)的近端阔筋膜张肌(FL)移植物结构是开放获取的,而大腿中部的FL移植物结构是微创获取的。本研究的目的是比较用于ASCR的大腿近端和大腿中部获取的FL移植物结构的生物力学特性。假设是,尽管用于ASCR的大腿近端和大腿中部FL移植物结构具有不同的形态特征,但其生物力学特性不会有显著差异。这些信息可能有助于骨科医生选择ASCR的取材部位、技术和移植物结构类型。
从10具新鲜人体尸体(6男,4女;平均年龄58.60±17.20岁)的大腿外侧获取40个FL标本,其中20个来自大腿近端,20个来自大腿中部。测量了每个两层的大腿近端和六层的大腿中部FL移植物结构的厚度。每个结构在纵向进行力学测试,并计算刚度和杨氏模量。数据通过韦尔奇独立t检验和方差分析进行比较,统计学显著性设定为P<0.05。
大腿近端FL移植物结构的平均厚度(7.17±1.97mm)显著高于大腿中部(5.54±1.37mm)[F(1,32)=7.333,P=0.011]。大腿近端和大腿中部移植物结构的平均杨氏模量分别为32.85±19.54MPa(范围7.94 - 75.14MPa;95%置信区间[CI],23.71 - 42.99)和44.02±31.29MPa(范围12.53 - 120.33MPa;95%CI,29.38 - 58.66)。大腿近端和大腿中部移植物结构的平均刚度分别为488.96±267.80N/mm(范围152.96 - 1086.49N/mm;95%CI,363.63 - 614.30)和562.39±294.76N/mm(范围77.46 - 1229.68N/mm;95%CI,424.44 - 700.34)。大腿近端和大腿中部移植物结构的平均杨氏模量或刚度之间无显著差异(分别为P=0.185和P=0.415)。
尽管用于ASCR的大腿近端和大腿中部FL移植物结构具有不同的形态特征,但其杨氏模量和刚度无显著差异。