Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand.
Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand.
Food Chem. 2021 Dec 1;364:130396. doi: 10.1016/j.foodchem.2021.130396. Epub 2021 Jun 17.
A histamine biosensor was developed based on a screen-printed carbon electrode modified with Prussian blue (PB) electrodeposited on multi-walled carbon nanotubes covered with a macroporous layer of chitosan-gold nanoparticles composite cryogel (CS-AuNPs Cry). With its high specific surface area and conductivity, CS-AuNPs Cry proved an excellent supporting material for diamine oxidase (DAO) immobilization. PB acted as a redox mediator to promote electron transfer between hydrogen peroxide and the electrode surface. The PB reduction current was measured during the hydrogen peroxide-releasing oxidation of histamine catalyzed by DAO. The proposed biosensor displayed two linear ranges: 2.50-125.0 µmol L and 125.0-400.0 µmol L. The limit of detection was 1.81 µmol L. Reproducibility was good (RSD = 5.46%), operational stability high, long-term stability excellent, and selectivity good. The biosensor determined histamine levels in fish and shrimps with satisfactory recoveries, and the obtained results agreed with those obtained by ELISA.
基于在多壁碳纳米管上沉积普鲁士蓝(PB)修饰的丝网印刷碳电极,研制了一种组胺生物传感器。多壁碳纳米管上覆盖着壳聚糖-金纳米粒子复合大孔层的 cryogel(CS-AuNPs Cry)。CS-AuNPs Cry 具有高比表面积和导电性,是二胺氧化酶(DAO)固定化的理想支撑材料。PB 作为氧化还原介体,促进了过氧化氢与电极表面之间的电子转移。在 DAO 催化组胺释放氧化过程中,测量 PB 还原电流。所提出的生物传感器显示出两个线性范围:2.50-125.0 μmol L 和 125.0-400.0 μmol L。检测限为 1.81 μmol L。重现性好(RSD=5.46%),操作稳定性高,长期稳定性好,选择性好。该生物传感器用于测定鱼类和虾类中的组胺含量,回收率令人满意,所得结果与 ELISA 法一致。