Vessani Roberto, Frota Thalyta, Shigetomi Gabriella, Correa Priscila, Mariottoni Eduardo B, Tavares Ivan
Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, São Paulo Hospital, Federal University of São Paulo, São Paulo, Brazil.
Clin Ophthalmol. 2021 Jul 14;15:3017-3026. doi: 10.2147/OPTH.S317190. eCollection 2021.
To evaluate the magnitude of change in optic disc, peripapillary retinal nerve fiber layer (RNFL) and macular parameters measured by swept-source optical coherence tomography (SS-OCT) in glaucomatous eyes after filtration surgery, and to determine any possible relationship between these measurements and baseline factors.
This multicenter, prospective, consecutive observational study included patients with open-angle glaucoma who required glaucoma filtering surgery (surgical group, 29 eyes) and those with stable disease (control group, 25 eyes). Patients from the surgical group underwent measurement of optic disc, peripapillary retinal nerve fiber layer (RNFL) and macular parameters before and after surgery.
In the surgical group, there was a significant increase in rim area and a significant decrease in the linear cup/disc ratio, vertical cup/disc ratio and cup volume 1 and 2 months postoperatively (p< 0.05). No significant change in the mean RNFL thickness and also sectorial measurements were observed from baseline to 1 and 2 months after surgery (p>0.05). Furthermore, significant increases in macular parameters were observed until 2 months after surgery (p<0.05). No significant changes were observed for all SS-OCT measurements in the control group. There was a significant correlation between the magnitude of the structural measurements change and the IOP reduction for two topographic parameters (rim area and linear cup-disc ratio) and macular average thickness 1 month and 2 months postoperatively.
In open-angle glaucoma patients submitted to surgical IOP reductions, improvements in topographic and macular OCT parameters measured by SS-OCT were observed for at least 2 months.
评估青光眼患者滤过手术后通过扫频光学相干断层扫描(SS-OCT)测量的视盘、视乳头周围视网膜神经纤维层(RNFL)和黄斑参数的变化幅度,并确定这些测量值与基线因素之间的任何可能关系。
这项多中心、前瞻性、连续观察性研究纳入了需要进行青光眼滤过手术的开角型青光眼患者(手术组,29只眼)和病情稳定的患者(对照组,25只眼)。手术组患者在手术前后接受视盘、视乳头周围视网膜神经纤维层(RNFL)和黄斑参数的测量。
手术组术后1个月和2个月时,视盘边缘面积显著增加,线性杯盘比、垂直杯盘比和杯容积显著降低(p<0.05)。从基线到术后1个月和2个月,平均RNFL厚度及扇形测量值均未观察到显著变化(p>0.05)。此外,直到术后2个月黄斑参数均显著增加(p<0.05)。对照组所有SS-OCT测量值均未观察到显著变化。术后1个月和2个月时,两个地形参数(视盘边缘面积和线性杯盘比)和黄斑平均厚度的结构测量值变化幅度与眼压降低之间存在显著相关性。
在接受手术降低眼压的开角型青光眼患者中,通过SS-OCT测量的地形和黄斑OCT参数至少在2个月内有所改善。