Spiotta Alejandro M, Park Min S, Bellon Richard J, Bohnstedt Bradley N, Schirmer Clemens M, De Leacy Reade A, Fiorella David J, Yoo Albert J, Dumont Travis M, Starke Robert M
Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina, USA.
Department of Neurosurgery, University of Virginia, Charlottesville, Virginia, USA.
World Neurosurg. 2021 Nov;155:e323-e334. doi: 10.1016/j.wneu.2021.08.043. Epub 2021 Aug 20.
The Prospective, Multicenter Registry Assessing the Embolization of Neurovascular Lesions Using the Penumbra SMART COIL® System (SMART) is the largest prospective, multicenter, postmarket registry established to gather real-world experience on Penumbra (Alameda, USA) SMART COIL System, PC400, and POD embolization coils. The goal of this study is to report the technical success and efficacy of SMART COIL System coils in treating saccular intracranial aneurysms.
This subgroup analysis from the SMART registry included patients with saccular intracranial aneurysms treated using ≥75% SMART COIL System or PC400 coils. Baseline and procedural data, angiographic data, and clinical outcomes were collected. Predictors of catheter kickout, packing density, and postprocedural angiographic outcome were analyzed using multivariable regression models in saccular aneurysm cases.
Between June 2016 and August 2018, the SMART registry enrolled 995 patients at 68 sites, of which 851 of 995 (85.5%) were treated for saccular aneurysms (mean age, 59.9 years). Aneurysms had a mean size of 6.8 mm, were wide neck in 63.1%, and ruptured in 31.0% of patients. Mean aneurysm packing density was 32.3%. Postprocedural Raymond-Roy Occlusion Classification (RROC) I-II was achieved in 80.3% of patients; smaller aneurysms, non-wide-neck aneurysms, and high packing density were predictive of RROC I-II. Overall, mean fluoroscopic time was 43.4 minutes, rate of reaccess attempts because of catheter kickout was 6.2%, and mean procedure time was 83.2 minutes.
SMART COIL System coils achieved good technical success and adequate occlusion in treating saccular intracranial aneurysms in a real-world setting.
前瞻性、多中心注册研究评估使用Penumbra SMART COIL®系统(SMART)栓塞神经血管病变,这是为收集有关Penumbra(美国阿拉米达)SMART COIL系统、PC400和POD栓塞线圈的真实世界经验而建立的最大规模前瞻性、多中心上市后注册研究。本研究的目的是报告SMART COIL系统线圈治疗颅内囊状动脉瘤的技术成功率和疗效。
来自SMART注册研究的该亚组分析纳入了使用≥75% SMART COIL系统或PC400线圈治疗的颅内囊状动脉瘤患者。收集基线和手术数据、血管造影数据及临床结局。在囊状动脉瘤病例中,使用多变量回归模型分析导管弹出、填充密度和术后血管造影结局的预测因素。
2016年6月至2018年8月期间,SMART注册研究在68个地点招募了995例患者,其中995例中的851例(85.5%)接受了囊状动脉瘤治疗(平均年龄59.9岁)。动脉瘤平均大小为6.8 mm,63.1%为宽颈,31.0%的患者动脉瘤破裂。平均动脉瘤填充密度为32.3%。80.3%的患者术后达到Raymond-Roy闭塞分级(RROC)I-II级;较小的动脉瘤、非宽颈动脉瘤和高填充密度是RROC I-II级的预测因素。总体而言,平均透视时间为43.4分钟,因导管弹出而再次尝试进入的发生率为6.2%,平均手术时间为83.2分钟。
在真实世界环境中,SMART COIL系统线圈在治疗颅内囊状动脉瘤方面取得了良好的技术成功率和充分的闭塞效果。