Department of Health and Exercise Science, Exercise Physiology Laboratory, Rowan University, Glassboro, New Jersey, USA.
Clin Physiol Funct Imaging. 2022 Jan;42(1):29-34. doi: 10.1111/cpf.12732. Epub 2021 Oct 23.
An appropriate comparison of different cuff widths during blood flow restricted exercise requires that the cuffs are inflated to the same relative pressures. Narrow cuffs tend to be preferred and may reduce discomfort when applied during resistance exercise, but whether this is also true during walking exercise remains unknown.
Individuals completed two identical walking trials, once with 12-cm wide cuffs and once with 17-cm wide cuffs. Five 2-min walking bouts were completed at a speed of 50 m/min, with a 1-min rest period between sets. The restriction cuffs were inflated to 40% of the individuals' arterial occlusion pressure taken with each respective cuff. Individuals were asked to rate their discomfort, perceived exertion (RPE), and cuff preference.
Twenty-seven individuals completed the study. The 12-cm cuff required a higher occlusion pressure which resulted in a higher absolute pressure applied (58 vs. 52 mm Hg; BF = 19 331.897). Whilst there was no difference in RPE values between cuffs (BF = 0.474), individuals reported greater discomfort when using the wider cuffs (2.3 vs. 1.7; BF = 252.786). The majority of individuals (63%) preferred to use the narrower cuff, whereas fewer preferred the wider cuff (26%) and even fewer did not have a preference (11%).
Blood flow restricted walking exercise performed with narrower restriction cuffs appeared to reduce participant discomfort whilst also being preferred over that of wider cuffs. Future studies may wish to test the influence of different restrictive cuff widths on alterations in gait patterns during blood flow restricted walking exercise.
在限制血流运动中,要使不同袖带宽度的比较适当,需要将袖带充气至相同的相对压力。较窄的袖带往往更受欢迎,并且在进行抗阻运动时应用可能会减少不适感,但在进行步行运动时是否也是如此尚不清楚。
个体完成了两次相同的步行试验,一次使用 12cm 宽的袖带,一次使用 17cm 宽的袖带。以 50m/min 的速度完成 5 个 2 分钟的步行回合,每组之间休息 1 分钟。限制袖带充气至每个袖带各自的动脉闭塞压的 40%。个体被要求对其不适感、感知用力(RPE)和袖带偏好进行评分。
27 名个体完成了该研究。12cm 袖带需要更高的闭塞压,从而导致施加的绝对压力更高(58 对 52mmHg;BF = 19331.897)。尽管袖带之间的 RPE 值没有差异(BF = 0.474),但个体在使用较宽袖带时报告了更大的不适感(2.3 对 1.7;BF = 252.786)。大多数个体(63%)更喜欢使用较窄的袖带,而较少的个体(26%)更喜欢使用较宽的袖带,甚至更少的个体(11%)没有偏好。
在使用较窄限制袖带进行的限制血流步行运动中,似乎可以减少参与者的不适感,并且也比较宽袖带更受欢迎。未来的研究可能希望测试不同限制袖带宽度对限制血流步行运动中步态模式改变的影响。