Abstract

This study aimed to decrease surgeon exposure to ionizing radiation through a new learning technique, "deliberate practice", which consists in improving performance by setting goals with feedback. The hypothesis was that exposure to ionizing radiation during distal radius fracture surgery using the minimally invasive plate osteosynthesis (MIPO) technique decreased faster with "deliberate" practice than with "naïve" practice. Radiographic dosimetry was measured in the first 30 fractures operated on by MIPO by 6 surgeons. The first 3 surgeons operated "naively" (Group 1) and the next 3 according to the "deliberate" procedure (Group 2). Group 2 received weekly feedback (number of exposed hands, number of fluoroscopic views, exposure duration, and X-ray dose). An expert, using fluoroscopic images and surgical videos, provided suggestions for improvement. Mean number of exposed hands was 23.66 in Group 1 and 1.9 in Group 2. Mean number of fluoroscopic views was 78.31 and 35.0, respectively. Mean X-ray exposure time was 74.34 and 32.89 s, respectively. Mean dosimetry was 1.40 mGy (and 0.59 mGy, respectively. The hypothesis was thus confirmed: dosimetry decreased faster in Group 2 than in Group 1. Teaching this deliberate practice should be generalized, to decrease the growth phase and increase the plateau phase of the learning curve.

摘要

本研究旨在通过一种新的学习技术“刻意练习”来减少外科医生暴露于电离辐射的风险,该技术通过设定带有反馈的目标来提高表现。假设使用微创钢板接骨术(MIPO)技术治疗桡骨远端骨折时,通过“刻意”练习比“盲目”练习更快地降低电离辐射暴露。对 6 名外科医生进行的前 30 例 MIPO 手术中的 30 例进行了放射剂量测定。前 3 名外科医生“盲目”操作(第 1 组),接下来 3 名外科医生根据“刻意”程序操作(第 2 组)。第 2 组每周收到反馈(暴露的手的数量、透视次数、曝光持续时间和 X 射线剂量)。一名专家使用透视图像和手术视频提供了改进建议。第 1 组中暴露的手的平均数量为 23.66,第 2 组为 1.9。透视次数的平均值分别为 78.31 和 35.0。X 射线曝光时间的平均值分别为 74.34 和 32.89 秒。平均剂量分别为 1.40 mGy(和 0.59 mGy)。因此,假设得到证实:第 2 组的剂量测定比第 1 组下降得更快。应该推广这种刻意练习的教学,以缩短学习曲线的增长阶段并增加平台阶段。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验