Abstract

There are advocates of both two-dimensional (2D) and three-dimensional (3D) templating methods for planning total hip replacement. The aim of this study was to compare the accuracy of implant size prediction when using 2D and 3D templating methods for total hip arthroplasty, as well as to compare the inter- and intra-observer reliability in order to determine whether currently available methods are sufficiently reliable and reproducible. Medline, EMBASE and PubMed were searched to identify studies that compared the accuracy of 2D and 3D templating for total hip replacement. Results were screened using the PRISMA flowchart and included studies were assessed for their level of evidence using the Oxford CEBM criteria. Non-randomized trials were critically appraised using the MINORS tool, whilst randomized trials were assessed using the CASP RCT checklist. A series of meta-analyses of the data for accuracy were also conducted. Ten studies reported that 3D templating is an accurate and reliable method of templating for total hip replacement. Six studies compared 3D templating with 2D templating, all of which concluded that 3D templating was more accurate, with three finding a statistically significant difference. The meta-analyses showed that 3D CT templating is the most accurate method. This review supports the hypothesis that 3D templating is an accurate and reliable method of preoperative planning, which is more accurate than 2D templating for predicting implant size. However, further research is needed to ascertain the significance of this improved accuracy and whether it will yield any clinical benefit.

摘要

在全髋关节置换手术规划中,二维(2D)和三维(3D)模板法都有其支持者。本研究的目的是比较在全髋关节置换术中使用2D和3D模板法时植入物尺寸预测的准确性,并比较观察者间和观察者内的可靠性,以确定当前可用的方法是否足够可靠和可重复。检索了Medline、EMBASE和PubMed,以识别比较2D和3D模板法在全髋关节置换术中准确性的研究。使用PRISMA流程图筛选结果,并根据牛津循证医学中心(CEBM)标准评估纳入研究的证据水平。使用MINORS工具对非随机试验进行严格评估,而使用CASP随机对照试验清单对随机试验进行评估。还对准确性数据进行了一系列荟萃分析。十项研究报告称,3D模板法是全髋关节置换术中一种准确且可靠的模板制作方法。六项研究将3D模板法与2D模板法进行了比较,所有研究均得出结论,3D模板法更准确,其中三项发现有统计学显著差异。荟萃分析表明,3D CT模板法是最准确的方法。本综述支持这一假设,即3D模板法是一种准确且可靠的术前规划方法,在预测植入物尺寸方面比2D模板法更准确。然而,需要进一步研究以确定这种提高的准确性的意义以及它是否会带来任何临床益处。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/16b0/8788155/7c28ae2b57b7/EOR-21-0060fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验