人唾液中 INCB000928 的生物分析:非特异性结合和不均匀浓度。

Bioanalysis of INCB000928 in human saliva: nonspecific binding and inhomogeneous concentration.

机构信息

Drug Metabolism & Pharmacokinetics & Clinical Pharmacology, Incyte Research Institute, 1801 Augustine Cut-off, Wilmington, DE 19803, USA.

出版信息

Bioanalysis. 2022 Apr;14(7):405-419. doi: 10.4155/bio-2022-0016. Epub 2022 Mar 10.

Abstract

To develop a bioanalytical method for quantifying INCB000928 in human saliva. Human centrifuged saliva and human whole saliva were compared for matrix selection. Protein precipitation extraction and HPLC-MS/MS was used for analysis. Nonspecific binding of INCB000928 was reduced in whole versus centrifuged saliva. Whole saliva was a preferred matrix for INCB000928 bioanalytical method validation. Incurred sample reanalysis (ISR) using a successfully validated method failed in a healthy volunteer study because of inhomogeneous INCB000928 concentration across sample tube depths. Individual mixing of sample tubes followed by immediate aliquoting corrected the ISR failure, with 97.2% of repeats passing versus 41.7% for the same ISR samples.

摘要

开发一种用于定量测定人唾液中 INCB000928 的生物分析方法。比较了人离心唾液和全唾液作为基质选择。采用蛋白沉淀提取和 HPLC-MS/MS 进行分析。与离心唾液相比,全唾液中 INCB000928 的非特异性结合减少。全唾液是 INCB000928 生物分析方法验证的首选基质。在健康志愿者研究中,使用经过验证的方法进行了实例样本重新分析(ISR),但由于样本管深度的 INCB000928 浓度不均匀,导致 ISR 失败。对样本管进行单独混合,然后立即等分,纠正了 ISR 失败,97.2%的重复样本通过,而相同的 ISR 样本为 41.7%。