Suppr超能文献

在实际活动中使用了多少髋关节运动?可穿戴传感器评估髋关节屈曲度及全髋关节置换术后的影响。

How Much Hip Motion Is Used in Real-Life Activities? Assessment of Hip Flexion by a Wearable Sensor and Implications After Total Hip Arthroplasty.

机构信息

Institute for Joint Restoration, Center for Joint Replacement Bldg, Fremont, California.

出版信息

J Arthroplasty. 2022 Aug;37(8S):S871-S875. doi: 10.1016/j.arth.2022.03.052. Epub 2022 Mar 18.

Abstract

BACKGROUND

Hip range of motion precautions are often considered a requirement for patients after total hip replacement. Few studies have attempted to estimate hip motion during activities of daily living. The purpose of this study is to evaluate hip range of motion and gait during real-life activities in healthy individuals with a novel tracking wearable sensor.

METHODS

Thirty subjects used a hip motion tracking device during a series of tested activities. Healthy volunteers were selected, and subjects were excluded if they reported symptoms in the limb or known deviation in their gait. Hip flexion was evaluated during common activities of daily living.

RESULTS

Hip range of motion during walking averaged minimum to maximum hip flexion of 9.9°-49.3°, respectively. During stair ascent, the average flexion arc widened from minimum 19.6° to maximum 67.8° flexion. Stair descent had the most narrow arc of 26.2°-52.4° hip flexion. Squatting averaged 120.0° of hip flexion, with the transition from sitting to standing averaging 103.0°. Getting on and off of the toilet averaged maximum 112.6°, while tying shoes averaged 126.1° maximum hip flexion.

CONCLUSION

Hip precautions are often enforced after total hip arthroplasty without knowing normal arcs of motion during real-life activities. Knowledge of hip motion during activities of daily living in healthy individuals is useful information in setting goals and in educating total hip arthroplasty patients. This technology can be useful in guiding postoperative precautions and also in monitoring patients after hip replacement with real-time monitoring.

摘要

背景

髋关节活动范围的预防措施通常被认为是全髋关节置换术后患者的要求。很少有研究试图估计日常生活活动中的髋关节运动。本研究的目的是使用新型跟踪可穿戴传感器评估健康个体在真实活动中的髋关节活动范围和步态。

方法

30 名受试者在一系列测试活动中使用髋关节运动跟踪装置。选择健康志愿者,如果他们报告肢体有症状或已知步态有偏差,则排除这些志愿者。评估了健康志愿者在日常生活活动中的髋关节屈曲情况。

结果

行走时髋关节活动范围的平均最小到最大髋关节屈曲分别为 9.9°-49.3°。在上楼梯时,平均屈曲弧从最小的 19.6°扩大到最大的 67.8°屈曲。下楼梯时髋关节屈曲的角度最窄,为 26.2°-52.4°。深蹲平均髋关节屈曲 120.0°,从坐立到站立的转换平均为 103.0°。上下厕所平均最大髋关节屈曲为 112.6°,系鞋带时平均最大髋关节屈曲为 126.1°。

结论

在不知道日常生活活动中正常活动范围的情况下,全髋关节置换术后通常会对髋关节进行预防措施。了解健康个体在日常生活活动中的髋关节运动是设定目标和教育全髋关节置换患者的有用信息。这项技术可用于指导术后预防措施,也可用于通过实时监测来监测髋关节置换后的患者。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验