Suppr超能文献

关节置换术后管理中急性继发部位并发症的MRI检查:植入髋关节和膝关节安全性问题的叙述性综述

MRI for an Acute Secondary Site Complication in Post-arthroplasty Management: Narrative Review of Safety Concerns for an Implanted Hip and Knee Joint.

作者信息

Tomar Lavindra, Govil Gaurav, Dhawan Pawan

机构信息

Department of Orthopedics, Max Super Speciality Hospital, Patparganj, Delhi, IND.

出版信息

Cureus. 2022 Feb 17;14(2):e22319. doi: 10.7759/cureus.22319. eCollection 2022 Feb.

Abstract

Arthroplasty in the elderly may present with acute or late-onset complications unrelated to an implanted arthroplasty joint. Magnetic resonance imaging (MRI) evaluation of an acute onset complication in the immediate post-arthroplasty scenario presents safety concerns. An arthroplasty surgeon's dilemma relates to the loosening, heating, or migration of implanted hip or knee joints. We present a representational case scenario for discussion. A hip arthroplasty patient presenting with hemiplegia in the immediate postoperative period necessitated an MRI evaluation for the brain with an additional angiogram. A knee arthroplasty patient presenting with lower limb weakness in the immediate postoperative period necessitated an MRI evaluation of the brain. Loosening of surgical metallic clips used for wound closure and the instability or loosening of recently implanted hip and knee joints pose significant safety concerns for the arthroplasty surgeon. The confirmatory diagnosis of the secondary site complication in the acute post-arthroplasty perioperative period, however, allowed the allied super-specialist to plan the management protocol. A review of the literature suggests that the use of nonferromagnetic elements in implanted joints with the use of cement or the press-fit method of implantation during arthroplasty has high safety margins. The staples used for wound closure have significant strength to hold the wound without any disruption or dehiscence during the MRI imaging. The metallic artifacts associated with an implanted joint do not interfere in the evaluation of the secondary site MRI. MRI can be safely done in a well-fixed joint of non-ferromagnetic elements. The review of literature also suggests that MRI can be done even in the presence of skin staples for the assessment of an acute secondary site complication in a post-arthroplasty patient. The risk-to-benefit ratio though needs to be applied for imaging a secondary site.

摘要

老年人的关节成形术可能会出现与植入的关节成形术关节无关的急性或迟发性并发症。在关节成形术后立即对急性并发症进行磁共振成像(MRI)评估存在安全问题。关节成形术外科医生面临的困境与植入的髋关节或膝关节的松动、发热或移位有关。我们提出一个代表性的病例场景以供讨论。一名髋关节成形术患者在术后立即出现偏瘫,需要进行脑部MRI评估及额外的血管造影。一名膝关节成形术患者在术后立即出现下肢无力,需要进行脑部MRI评估。用于伤口闭合的外科金属夹松动以及近期植入的髋关节和膝关节不稳定或松动,给关节成形术外科医生带来了重大安全问题。然而,在关节成形术后急性围手术期对继发部位并发症的确诊,使相关的专科医生能够制定治疗方案。文献综述表明,在关节成形术中使用非铁磁性元素的植入关节,并采用骨水泥或压配式植入方法,具有较高的安全系数。用于伤口闭合的吻合钉在MRI成像期间具有足够的强度来固定伤口,不会出现任何断裂或裂开。与植入关节相关的金属伪影不会干扰继发部位MRI的评估。在非铁磁性元素的固定良好的关节中,可以安全地进行MRI检查。文献综述还表明,即使存在皮肤吻合钉,也可以进行MRI检查,以评估关节成形术后患者的急性继发部位并发症。不过,在对继发部位进行成像时需要应用风险效益比。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ffd2/8934014/4ec552f697c6/cureus-0014-00000022319-i01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验