A highly-selective two-dimensional high-performance liquid chromatographic (2D-HPLC, off-line heart cutting mode) system was developed for the determination of serine (Ser), threonine (Thr) and allo-threonine (aThr) enantiomers in human physiological fluids. Ser, Thr and aThr have a hydroxy group in their side chains, and the development of a simultaneous analytical method with a practically sufficient enantio/chemo-selectivity has been required to clarify their amounts in human physiological fluids. The amino acids in the samples were derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole and were isolated by a reversed-phase column (Singularity RP18, 1.0 x 250 mm) in the first dimension. After the target amino acids were collected, the fractions were manually introduced into an enantioselective column in the second dimension and were detected by their fluorescence. For the second dimension, a Pirkle-type chiral stationary phase (Singularity CSP-013S, 1.5 x 250 mm) was used. The resolution values of the enantiomers obtained by the Singularity CSP-013S column were 7.64 for Ser, 7.58 for Thr and 4.71 for aThr by using the mixture of methanol and acetonitrile containing formic acid as the mobile phases. The developed method was validated and applied to human plasma and urine. In the plasma, the obtained %d values (the percentage of d-form to total amino acid) were 1.7 for Ser, and trace levels of d-aThr and d-Thr were observed. In the urine, the %d values were 48.0 for Ser, 1.6 for Thr and 8.0 for aThr (calculated using d-aThr and l-Thr).

摘要

开发了一种高选择性二维高效液相色谱(2D-HPLC,离线心脏切割模式)系统,用于测定人生理体液中的丝氨酸(Ser)、苏氨酸(Thr)和别苏氨酸(aThr)对映体。Ser、Thr 和 aThr 在其侧链上具有羟基,需要开发一种具有实际足够的对映体/化学选择性的同时分析方法,以阐明它们在人生理体液中的含量。样品中的氨基酸用 4-氟-7-硝基-2,1,3-苯并恶二唑衍生,并在第一维通过反相柱(Singularity RP18,1.0 x 250mm)分离。在目标氨基酸被收集后,将馏分手动引入第二维的对映选择性柱中,并通过其荧光进行检测。对于第二维,使用 Pirkle 型手性固定相(Singularity CSP-013S,1.5 x 250mm)。使用甲醇和乙腈与甲酸混合作为流动相,通过 Singularity CSP-013S 柱获得的对映体的分辨率值分别为 Ser 的 7.64、Thr 的 7.58 和 aThr 的 4.71。开发的方法经过验证并应用于人血浆和尿液。在血浆中,获得的%d 值(d-形式与总氨基酸的百分比)为 Ser 的 1.7,并且观察到痕量的 d-aThr 和 d-Thr。在尿液中,%d 值分别为 Ser 的 48.0、Thr 的 1.6 和 aThr 的 8.0(使用 d-aThr 和 l-Thr 计算)。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验