Assessment of formaldehyde exposures under contemporary embalming conditions in U.S. funeral homes.

机构信息

Cardno ChemRisk, now Stantec, Pittsburgh, Pennsylvania.

Cardno ChemRisk, now Stantec, San Francisco, California.

出版信息

J Occup Environ Hyg. 2022 Jul;19(7):425-436. doi: 10.1080/15459624.2022.2076861. Epub 2022 Jun 3.

Abstract

The funeral service profession has used formaldehyde-containing embalming solutions for the preparation of decedents since the early 1900s. The available literature regarding funeral director exposure to formaldehyde largely consists of data collected prior to 2000, with most studies reporting task-length exposure concentrations rather than full-shift time-weighted average concentrations. As formaldehyde undergoes review in the U.S. Environmental Protection Agency Toxic Substances Control Act (TSCA) risk evaluation process, accurately characterizing long-term exposure potential in this profession is critical. This study presents passive badge sampling and air change rate measurement results conducted at 13 funeral home locations across the United States. Full-shift (approximately 8-hr) samples were collected on one embalmer per day in each funeral home and on one occupational non-user (ONU), e.g., a receptionist. Additionally, task-length samples were collected during each embalming that occurred during the shift, were one to occur. Full-shift concentrations ranged from 0.007 to 1.1 ppm and 0.007 to 0.042 ppm for embalmers and ONUs, respectively. Task-length formaldehyde concentrations ranged from 0.058 to 1.4 ppm, with the average embalming taking 72.8 min to complete. Air change rates in the preparation rooms ranged from 2.8 to 28.3 air changes per hour; however, no correlation between task-length formaldehyde concentrations and air change rate was observed. Following empirical data collection, a Monte Carlo analysis of estimated annual 8-hr time-weighted average (TWA) exposure was conducted to determine the potential exposure distribution for embalmers employed at private funeral homes. Inputs to the simulation were derived from responses to a National Funeral Directors Association survey and from empirical measurements collected during the study. With respect to the reconstructed 8-hr TWAs, the median 8-hr TWA was 0.037 ppm, with 93.6% of the predicted concentrations below 0.1 ppm. This study provides a robust characterization of contemporary formaldehyde exposures in the funeral service profession. Further, it provides a strategy for interpreting the results along with surveyed responses regarding embalming frequency to better inform risks associated with formaldehyde exposure in this profession.

摘要

自 20 世纪初以来,丧葬服务行业一直在使用含有甲醛的防腐液来处理死者。关于殡仪馆馆长接触甲醛的文献主要包括 2000 年之前收集的数据,其中大多数研究报告的是任务长度暴露浓度,而不是全班时间加权平均浓度。由于甲醛在美国环境保护署有毒物质控制法(TSCA)风险评估过程中进行审查,因此准确描述该行业的长期暴露潜力至关重要。本研究介绍了在美国 13 家殡仪馆进行的被动徽章采样和空气交换率测量结果。在每个殡仪馆,每天对一名防腐师进行一次全班(约 8 小时)采样,对一名职业非使用者(ONU),例如接待员,也进行了一次采样。此外,在全班期间发生的每次防腐处理过程中,都采集了任务长度的样本。防腐师和 ONU 的全班浓度分别为 0.007 至 1.1ppm 和 0.007 至 0.042ppm。任务长度的甲醛浓度范围为 0.058 至 1.4ppm,平均每次防腐处理需要 72.8 分钟完成。准备室的空气交换率范围为 2.8 至 28.3 次/小时;然而,未观察到任务长度甲醛浓度与空气交换率之间的相关性。在进行经验数据收集之后,对私营殡仪馆防腐师的估计年 8 小时时间加权平均值(TWA)暴露进行了蒙特卡罗分析,以确定潜在的暴露分布。模拟的输入来自全国殡仪馆馆长协会调查的答复以及研究期间收集的经验测量值。就重建的 8 小时 TWA 而言,中位数 8 小时 TWA 为 0.037ppm,预测浓度中有 93.6%低于 0.1ppm。本研究对丧葬服务行业当代甲醛暴露进行了强有力的描述。此外,它提供了一种解释结果的策略,同时还对防腐频率进行了调查答复,以更好地告知该行业中与甲醛暴露相关的风险。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验