Huang Heng-Li, Tsai Hui-Ling, Wu Yu-Ling, Hsu Jui-Ting, Wu Aaron Yu-Jen
School of Dentistry, China Medical University, 91 Hsueh-Shih Road, Taichung 40402, Taiwan.
Department of Bioinformatics and Medical Engineering, Asia University, Taichung 41354, Taiwan.
Materials (Basel). 2022 May 4;15(9):3295. doi: 10.3390/ma15093295.
Residual alveolar ridge resorption often occurs after tooth extraction, which causes issues requiring further prothesis rehabilitation. A treatment concept referred to as all-on-four, involving fixed dentures supported with four implants, was recently developed. The current study aimed to determine the effect of changing bone atrophy and implant length in all-on-four treatments on stress and strain in the surrounding bone of the implant. A three-dimensional finite element method was used in this research. The stress analysis was conducted with von Mises stress values. Two types of synthetic jawbone models with mild and moderate atrophy were used. Furthermore, two different implant lengths with a similar implant design and diameter were selected, and they were classified into eight models. Then, the bone model was assessed via a computed tomography (CT) scan and was transformed into a virtual model in Geomagic and SolidWorks with implant rebuilding. After modifying bone atrophy, the von Mises stresses in the surrounding bone of the implant were as follows: mild type 2 < mild type 3 < moderate type 3 < moderate type 4. The bone quantity change rate increased more than when bone conditions were limited. Compared with changes in implant lengths, the stresses in the peri-implant surrounding bone were generally higher in the 9 mm implant length group than in the 11.5 mm group. However, the results did not significantly differ. In conclusion, the von Mises stress and strain increased in the models with moderate atrophy and low-density trabecular bone. Hence, bone atrophy and its presurgical diagnosis in long-term implant prognosis are crucial.
剩余牙槽嵴吸收常在拔牙后发生,这会引发一些需要进一步进行修复重建的问题。一种名为“all-on-four”的治疗理念最近被提出,该理念涉及用四颗种植体支持的固定义齿。本研究旨在确定在“all-on-four”治疗中改变骨萎缩和种植体长度对种植体周围骨的应力和应变的影响。本研究采用三维有限元方法。通过冯·米塞斯应力值进行应力分析。使用了两种具有轻度和中度萎缩的合成颌骨模型。此外,选择了两种具有相似种植体设计和直径但不同长度的种植体,并将它们分为八个模型。然后,通过计算机断层扫描(CT)对骨模型进行评估,并在Geomagic和SolidWorks中通过种植体重建将其转换为虚拟模型。改变骨萎缩后,种植体周围骨的冯·米塞斯应力如下:轻度2型<轻度3型<中度3型<中度4型。骨量变化率的增加幅度大于骨条件受限的情况。与种植体长度的变化相比,种植体周围骨的应力在9mm种植体长度组中通常高于11.5mm组。然而,结果差异不显著。总之,在中度萎缩和低密度小梁骨的模型中,冯·米塞斯应力和应变增加。因此,骨萎缩及其术前诊断对长期种植预后至关重要。