Suppr超能文献

254 例陶瓷涂层植入物(CCI)全踝关节置换的长期随访。

Long-term Follow-up of 254 Ceramic Coated Implant (CCI) Evolution Total Ankle Replacements.

机构信息

Department of Orthopedic Surgery, Noordwest Ziekenhuisgroep, Alkmaar, the Netherlands.

Specilized Centre for Orthopeadic Research & Education (SCORE), Department of Orthopedic Surgery, Xpert Clinics, Amsterdam, the Netherlands.

出版信息

Foot Ankle Int. 2022 Oct;43(10):1285-1294. doi: 10.1177/10711007221108084. Epub 2022 Jul 3.

Abstract

BACKGROUND

The ceramic coated implant (CCI) Evolution was a third-generation implant design used in approximately 2000 total ankle replacements (TARs) between 2003 and 2016. Because this implant was abandoned, long-term follow-up studies are lacking.

METHODS

All patients undergoing TAR using a CCI prosthesis between 2004 and 2012 were included for analysis. Preoperatively the tibiotalar alignment was measured, and postoperatively the patients were followed up clinically, with radiographs and by questionnaire. The primary outcome was implant survival at 10 years of follow-up. Implant survival was also compared for (1) inflammatory joint disease vs noninflammatory joint disease and (2) preoperative tibiotalar neutral vs varus or valgus alignment. The secondary outcomes were complications, reoperations, and function (assessed by patient-reported outcome measures).

RESULTS

Two hundred fifty-four TARs were performed in 237 patients. Two hundred twelve additional procedures were performed to achieve stable ankles. At 10-year follow-up, the survival was 67.5%, with an average time to revision of 4.5 years. The 10-year survival of the inflammatory joint disease group was 76.8% and of the noninflammatory joint group 63.1% ( = .44). In 248 TARs, the preoperative tibiotalar alignment was measured; (62% neutral, 25% varus, and 13% valgus), these showed 10-year survival rates of 74.7%, 48.2%, and 68.9% respectively ( = .07). The complication rate was 54%; 37% of patients underwent reoperation. At a mean of 8.5 years, postoperative satisfaction scored an average of 7.0 (SD 2.26) on a 0- to 10-point numeric rating scale. The mean Foot and Ankle Ability Measure sports subscore was 24.7, the mean Foot and Ankle Outcome Score (FAOS) sports subscore was 42.8, and the mean 36-Item Short Form Health Survey score was 40.0. Regarding daily activities, the mean FAOS was 81.0.

CONCLUSION

This is currently the sole study reporting the long-term results of the CCI prosthesis. The survival and functional outcomes were inferior to other third-generation mobile-bearing ankle implants.

摘要

背景

陶瓷涂层植入物(CCI)Evolution 是第三代植入物设计,于 2003 年至 2016 年间在约 2000 例全踝关节置换术(TAR)中使用。由于该植入物已被弃用,因此缺乏长期随访研究。

方法

纳入 2004 年至 2012 年间使用 CCI 假体进行 TAR 的所有患者进行分析。术前测量距下关节对线,术后通过临床检查、影像学检查和问卷调查进行随访。主要结局是 10 年随访时的植入物存活率。还比较了(1)炎性关节病与非炎性关节病和(2)术前距下中立与内翻或外翻对线的植入物存活率。次要结局是并发症、再次手术和功能(通过患者报告的结果测量)。

结果

237 例患者共进行了 254 例 TAR,为实现稳定的踝关节又进行了 212 例附加手术。10 年随访时,存活率为 67.5%,平均翻修时间为 4.5 年。炎性关节病组的 10 年存活率为 76.8%,非炎性关节病组为 63.1%(=.44)。在 248 例 TAR 中测量了术前距下关节对线;(62%中立,25%内翻,13%外翻),这些患者的 10 年存活率分别为 74.7%、48.2%和 68.9%(=.07)。并发症发生率为 54%;37%的患者接受了再次手术。平均 8.5 年后,术后满意度在 0 到 10 分的数字评分量表上平均得分为 7.0(SD 2.26)。平均足部和踝关节能力测量运动子评分 24.7,平均足部和踝关节结局评分(FAOS)运动子评分 42.8,平均 36 项简明健康调查量表评分 40.0。关于日常活动,FAOS 的平均得分为 81.0。

结论

这是目前唯一报道 CCI 假体长期结果的研究。存活率和功能结果劣于其他第三代活动式承重踝关节植入物。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验