Soft-tissue response to total hip surface replacement.

作者信息

Skinner H B, Mabey M F

出版信息

J Biomed Mater Res. 1987 May;21(5):569-84. doi: 10.1002/jbm.820210504.

Abstract

Tissue reaction to prosthesis wear debris and its relationship to prosthetic loosening was investigated. Eighteen dogs underwent hip surface replacement; 6 animals accounted for 6 control and 6 carbon hips, and 13 experimental animals accounted for 13 implanted carbon and 13 cobalt-chromium-molybdenum (CoCrMo) prostheses. Both kinds of prostheses articulated against a high-density polyethylene acetabular component. One year after implantation, tissue response to the prostheses was evaluated according to a semiquantitative method, and a total tissue score indicating the degree of tissue response was obtained. The total tissue score was then compared with the normalized final vertical ground reaction force (GRF) for each hip in the animals with bilateral hip replacements. Compared with the controls, significantly greater tissue response was seen in both kinds of prosthetic hips (p = .001). No statistically significant difference in the tissue response of the two types of hip prostheses was noted, although the tissue response score of the CoCrMo demonstrated a trend toward more severe reaction than the carbon. No statistical difference in tissue reaction was noted for loosened components as compared with tightly fixed components. Amount of wear debris was the best predictor of component loosening. Gait analysis demonstrated a statistically significant negative correlation between GRF and total tissue score (p = .036), and between GRF and wear debris score (p = .034). The results of this study suggest that GRF may predict the amount of wear debris in the tissues surrounding a total hip surface arthroplasty, and that severity of pain is related to the degree of tissue response.

摘要

研究了组织对假体磨损碎屑的反应及其与假体松动的关系。18只狗接受了髋关节表面置换;6只动物作为对照组,植入6个碳质髋关节假体,13只实验动物植入13个碳质和13个钴铬钼(CoCrMo)假体。两种假体均与高密度聚乙烯髋臼部件相铰接。植入一年后,根据半定量方法评估组织对假体的反应,并获得表示组织反应程度的总组织评分。然后将总组织评分与双侧髋关节置换动物中每个髋关节的标准化最终垂直地面反作用力(GRF)进行比较。与对照组相比,两种假体髋关节的组织反应明显更大(p = 0.001)。尽管CoCrMo假体的组织反应评分显示出比碳质假体更严重反应的趋势,但两种类型髋关节假体的组织反应在统计学上没有显著差异。与固定紧密的部件相比,松动部件的组织反应没有统计学差异。磨损碎屑量是部件松动的最佳预测指标。步态分析表明,GRF与总组织评分之间存在统计学上的显著负相关(p = 0.036),GRF与磨损碎屑评分之间也存在统计学上的显著负相关(p = 0.034)。本研究结果表明,GRF可能预测全髋关节表面置换周围组织中的磨损碎屑量,并且疼痛的严重程度与组织反应程度有关。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验