Department of General, Visceral and Transplantation Surgery, University Hospital of Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany.
Department of Internal Medicine VIII, Pulmonology and Oncology, University Hospital of Tübingen, Otfried-Müller-Str. 10, 72076, Tübingen, Germany.
Sci Rep. 2022 Aug 16;12(1):13889. doi: 10.1038/s41598-022-17700-3.
Endoscopic negative pressure therapy is an effective treatment strategy for various defects of the gastrointestinal tract. The functional principle is based on an open-pore element, which is placed around a perforated drainage tube and connected to a vacuum source. The resulting open-pore suction device can undergo endoluminal or intracavitary placement. Different open-pore suction devices are used for endoscopic negative pressure therapy of upper gastrointestinal tract defects. Comparative analyses for features and properties of these devices are still lacking. Eight different (six hand-made devices and two commercial devices) open-pore suction devices for endoscopic negative pressure therapy of the upper gastrointestinal tract were used, amount fluid removed was evaluated. The evaluation parameters included the time to reach the target pressure, the time required to remove 100 ml of water, and the material resistance of the device. All open-pore suction devices are able to aspirate the target volume of fluids. The time to reach the target volume varied considerably. Target negative pressure was not achieved with all open-pore suction devices during the aspiration of fluids; however, there was no negative effect on suction efficiency. Of the measurement data, material resistance could be calculated for six open-pore elements. We present a simple experimental, nonphysiologically setup for open-pore suction devices used for endoscopic negative pressure therapy. The expected quantity of fluids secreted into the treated organs should affect open-pore suction device for endoscopic negative pressure therapy.
内镜下负压治疗是一种治疗胃肠道各种缺损的有效策略。其功能原理基于一个开孔元件,该元件放置在穿孔引流管周围,并连接到真空源。由此产生的开孔抽吸装置可进行内镜腔内或腔内置入。不同的开孔抽吸装置用于治疗上消化道缺损。这些装置的特点和性能的比较分析仍然缺乏。使用了 8 种不同的(6 种手工制作的装置和 2 种商业装置)用于上消化道内镜下负压治疗的开孔抽吸装置,评估了去除的液体量。评估参数包括达到目标压力的时间、去除 100ml 水所需的时间以及装置的材料阻力。所有开孔抽吸装置都能够抽吸目标体积的液体。达到目标体积的时间差异很大。在抽吸液体过程中,并非所有的开孔抽吸装置都能达到目标负压;然而,这对抽吸效率没有负面影响。在测量数据中,可计算出 6 个开孔元件的材料阻力。我们提出了一种简单的实验性、非生理的开孔抽吸装置设置,用于内镜下负压治疗。预计进入治疗器官的分泌液量会影响用于内镜下负压治疗的开孔抽吸装置。