Maguire L J, Klyce S D, Sawelson H, McDonald M B, Kaufman H E
Ophthalmic Surg. 1987 May;18(5):352-6.
A patient experienced marked visual distortion following myopic keratomileusis, despite the presence of a clear graft and an apparently smooth corneal surface. A color coded topographic map of corneal surface power generated by computer analysis of a keratoscope photograph of the operated eye identified a degree of irregular astigmatism and asphericity not readily apparent from simple visual inspection of the keratoscope photograph. Contour map graphics display of corneal surface power is a useful clinical tool in the evaluation of visual distortion complications following myopic keratomileusis.