Hospital for Special Surgery, New York City, New York.
Footbridge Clinic, Vancouver, BC, Canada.
Foot Ankle Spec. 2023 Jun;16(3):288-299. doi: 10.1177/19386400221139525. Epub 2022 Dec 8.
The Trabecular Metal (Zimmer Biomet, Warsaw, IN) total ankle arthroplasty (TAA) system uses a lateral approach with a fibular osteotomy to gain access to the tibiotalar joint and a sagittally curved tibial component. This is the first TAA system to laterally approach the ankle, and few studies have explored outcomes associated with this implant. This study aimed to report the 5-year clinical and radiographic outcomes as well as the survivorship of the implant.
Over a 3-year period, 2 fellowship-trained foot and ankle surgeons used this implant system to treat 38 end-stage arthritic ankles. Reoperation and revision data were collected from all patients (100%) as part of the local prospective database. Patients completed the Foot and Ankle Outcome Score (FAOS) questionnaire preoperatively and at each annual follow-up visit; scores for a minimum of 5 years were available for 28 (73.7%) patients. A radiographic analysis compared postoperative coronal and sagittal alignment in weightbearing radiographs at a minimum of 5 years with that at 3 months postoperatively, as well as cyst or lucency formation, which was available for 21 patients (55.3%).
At 5 years, there were 3 revisions (7.9%) and 9 reoperations (23.7%). Reoperations included 4 fibular hardware removal and 5 medial gutter debridement procedures. The FAOS significantly improved for all domains (P < .05). Implant positioning did not significantly change between 3 months and 5 years postoperatively.
Our 5-year results in this small series using this unique prosthesis showed good overall survivorship (92.1%) and a reoperation rate of 23.7%, along with clinically significant improvement in patient-reported outcomes.
Level IV: Retrospective case series.
Trabecular Metal(Zimmer Biomet,印第安纳州华沙)全踝关节置换术(TAA)系统采用外侧入路和腓骨截骨术来进入距下关节,并采用矢状弯曲的胫骨部件。这是第一个采用外侧入路的 TAA 系统,很少有研究探讨与该植入物相关的结果。本研究旨在报告该植入物的 5 年临床和影像学结果以及存活率。
在 3 年期间,2 名接受过足踝 fellowship培训的外科医生使用该植入物系统治疗了 38 例晚期关节炎踝关节。所有患者(100%)的再手术和翻修数据均从当地前瞻性数据库中收集。患者在术前和每年随访时完成足踝结局评分(FAOS)问卷;28 例(73.7%)患者至少有 5 年的评分数据。在至少 5 年的时间内,对负重位 X 线片上的术后冠状位和矢状位对线与术后 3 个月的对线进行比较,并对 21 例(55.3%)患者的囊变或透亮线形成进行比较。
5 年内有 3 例(7.9%)进行了翻修,9 例(23.7%)进行了再手术。再手术包括 4 例腓骨内固定物取出和 5 例内侧沟清理术。所有领域的 FAOS 均显著改善(P <.05)。术后 3 个月和 5 年内,植入物位置没有明显变化。
在这个小系列中,使用这种独特的假体,我们的 5 年结果显示出良好的总体存活率(92.1%)和 23.7%的再手术率,以及患者报告的结果有显著改善。
IV 级:回顾性病例系列。